Check whether the SMF record type for MAR specified by the system symbol or the metric collection parameter has been correctly set for the SMFPRMxx parmlib member, and then take appropriate action.
  1. Check whether the specifications for the SMFPRMxx parmlib member are as follows:
    • For the TYPE or NOTYPE option of the SYS or SUBSYS parameter, the settings to collect the SMF record type for MAR are specified.
    • When the output destination of SMF records is a log stream (the value of the RECORDING parameter is LOGSTREAM), the SMF record type for MAR is specified for the TYPE option of the LSNAME parameter.
    • When SMF record flood support is active (the FLOODPOL parameter has been specified), the SMF record type for MAR is not specified for the TYPE option of the FLOODPOL parameter.

      If the SMF record type is specified here, records are not output when SMF records have a high output frequency.

    • When an SMF exit routine is specified for the EXITS parameter, output of SMF records for MAR in the exit routine is not suppressed.
  2. If the settings are different from the above, correct the settings by using one of the following methods:
    • Correct the settings of the SMFPRMxx parmlib member, and then apply the change by using the SET SMF=xx command.
    • Dynamically replace the values of the parameters by using the SETSMF command.

Reference information

For details, see the IBM manual MVS Initialization and Tuning Reference.