Syntax of metric collection parameters

Mainframe Analytics Recorder User Guide

Version
10.1.x
Audience
anonymous
Part Number
MK-92HC226-08
ft:lastEdition
2026-01-30
The following describes the syntax of metric collection parameters.

Syntax

[INTERVAL {SYNCSMF
          |[INTVAL(interval-value)] SYNCVAL(sync-value)}]

[METRIC   [LDEV] [MPU] [PGRP] [PORT] [MPRANK20]]

HDA       PREFIX(prefix)
          SN(serial-number[,serial-number]...)

[LDEVFILT [DEVN(start-DEVN[:end-DEVN][,start-DEVN[:end-DEVN]]...)]
          [VOLSER(volser[,volser]...)]
          [STORGRP(SMS-group[,SMS-group]...)]
          [ACTSS(subchannel-set-ID)]]

[LDEVALL  {SN(serial-number[,serial-number]...)
          |SN(serial-number) CU(CU-number[,CU-number]...)}]

SET       IODEVN(I/O-DEVN[,I/O-DEVN]...)
          [RTYPE(SMF-record-type)]

Parameters

INTERVAL

Metric collection interval.

If you omit the INTERVAL parameter or if you specify the INTERVAL parameter and omit the operands, the default value is SYNCSMF.

  • SYNCSMF

    Synchronizes the metric collection interval with the SMF global recording interval.

  • INTVAL(interval-value)~<numeric character>((1 to 60)) <<30>>

    Specify the interval (in minutes) for collecting metric information. Specify a divisor of 60.

  • SYNCVAL(sync-value)~<numeric character>((0 to 59))

    Specify the time (the number of minutes past the hour) at which the SMF records are to be recorded each hour.

    Metric collection starts at the time specified for the SYNCVAL operand, and then metric information is collected at the intervals specified for the INTVAL operand.

    For example, if you specify 15 for INTVAL and 30 for SYNCVAL, collection starts at 0 minutes, 15 minutes, 30 minutes, and 45 minutes for every hour. If the value specified for INTVAL is not a divisor of 60, only the first interval is synchronized at the time specified for SYNCVAL.

Tip:
To synchronize the metric collection interval with the RMF interval, specify as follows:
  • If the SYNC(SMF) option is used by RMF, specify the SYNCSMF operand.

  • If the SYNC(SMF) option is not used by RMF, specify values for the INTVAL operand and the SYNCVAL operand to match the RMF settings.

METRIC~<<all metrics>>

Metrics whose information is to be collected.

  • LDEV

    Collects LDEV information.

  • MPU

    Collects MPU information.

    For compatibility with earlier versions, the MPB parameter is allowed. It is equivalent to the MPU parameter.

  • PGRP

    Collects parity group information.

  • PORT

    Collects port information.

  • MPRANK20

    Collects information about the top 20 resources with the highest MP usage.

HDA
  • PREFIX(prefix)~<prefix consisting of 25 or fewer characters>

    Prefix of the disk configuration definition file. Specify the same value as the value specified for the PREFIX parameter of the disk configuration acquisition program when the disk configuration definition file was created.

  • SN(serial-number[,serial-number]...)~<5 alphanumeric characters>

    Serial number of the storage system whose disk configuration definition file is to be read.

    You can specify a maximum of 64 operand values.

LDEVFILT

Specify this parameter if you want to collect information from some (but not all) of the volumes recorded in the disk configuration definition file. If you do not specify the LDEVFILT and LDEVALL parameters, information about all volumes recorded in the disk configuration definition file will be collected.

The LDEVFILT parameter is valid only when LDEV information is set to be collected.

  • DEVN(start-DEVN[:end-DEVN][,start-DEVN[:end-DEVN]]...)~<5 or fewer hexadecimal characters>((00000 to 3FFFF))

    The device numbers of the volumes for which information is to be collected.

    To specify a range of device numbers, enter a colon (:) between the numbers of the first and last devices. To specify multiple values, delimit the values by using commas (,).

    You can specify a maximum of 64 operand values.

    When multiple subchannel sets are used:

    To collect from a specific subchannel set, either specify the subchannel set ID for the first digit and the device number for the last four digits, or omit the subchannel set ID and then specify the ACTSS operand. To collect from all of the subchannel sets, omit the ACTSS operand.

    To specify a range by specifying subchannel set IDs, specify the same subchannel set ID for both the start and end subchannel set IDs.

  • VOLSER(volser[,volser]...)~<6 or fewer alphanumeric characters>

    The volume serial numbers of the volumes whose information is to be collected.

    To specify multiple values, delimit the values by using commas (,). You can specify an asterisk (*) as a wild card at the end of the character string.

    You can specify a maximum of 64 operand values.

    When multiple subchannel sets are used:

    To collect from a specific subchannel set, specify the ACTSS operand.

    To collect from all of the subchannel sets, omit the ACTSS operand. Information about the volumes that have the same device number as the specified volumes is collected.

  • STORGRP(SMS-group[,SMS-group]...) ~ <symbolic name consisting of 8 or fewer characters>

    Names of the SMS storage groups from which information is to be collected.

    To specify multiple values, delimit the values by using commas (,).

    You can specify a maximum of 64 operand values.

    When multiple subchannel sets are used:

    To collect from a specific subchannel set, specify the ACTSS operand.

    To collect from all of the subchannel sets, omit the ACTSS operand. Information about the volumes that have the same device numbers as the volumes in the specified SMS storage groups.

  • ACTSS(subchannel-set-ID)~<0 to 3>

    Specify if you are going to collect information from a specific subchannel set when multiple subchannel sets are used. If there is a volume that does not exist in the specified subchannel set, information about the volumes in subchannel set 0 is to be collected.

    If you omit the ACTSS operand, information is collected from all of the subchannel sets.

Note:

When multiple subchannel sets are used and the DEVN operand that specified the subchannel set ID and the ACTSS operand are both specified, information about the volumes in the subchannel set specified by the DEVN operand is collected.

LDEVALL

Specify this parameter if you want to collect information about Non Gen'ed volumes.

The LDEVALL parameter is valid only when LDEV information is set to be collected.

You can specify the LDEVALL parameter more than once. If the storage system serial numbers specified for the SN operands are different, all parameters are valid. If the storage system serial numbers are the same, the parameter specified last is valid.

  • SN(serial-number[,serial-number]...)~<5 alphanumeric characters>

    Serial number of the storage system for which information is to be collected. Specify the storage system serial number that is specified for the operand to the SN operand of the HDA parameter.

    You can specify a maximum of 64 operand values.

  • CU(CU-number[,CU-number]...)~<two hexadecimal characters>((00-FE))

    Specify this operand if you want to collect information for all volumes in a specific CU of the storage system specified by the SN operand.

    The CU operand is specified for a specific storage system. Therefore, to collect the LDEV information of multiple storage systems, you must specify the LDEVALL parameter multiple times.

    You can specify a maximum of 255 operand values.

SET
  • IODEVN(I/O-DEVN[,I/O-DEVN]...)~<5 or fewer hexadecimal characters>((00000 to 3FFFF))

    Device number of the volume (I/O destination device) that is used by MAR to acquire performance information.

    Specify the device number (of the volume in the disk configuration definition file) specified for the SN operand of the HDA parameter.

    Specify at least one I/O destination device for each storage system. To improve fault tolerance and performance, we recommend that you specify more than one device number for each storage system.

    The storage systems containing the volumes to be specified as the I/O destination devices must be connected to the host by paths.

    You can specify a maximum of 128 operand values.

    When multiple subchannel sets are used:

    To specify the subchannel set, specify the subchannel set ID for the first digit, and the device number for the last four digits. If you omit the subchannel set ID, the volumes of subchannel set 0 are used.

  • RTYPE(SMF-record-type)~<numeric character>((128 to 255)) <<value-of-the-system-symbol-&RSRTYPE or 191>>

    Record type of the SMF records to be output by MAR.

    Specify a number that has not already been used for other record types.

    If you do not specify this operand, the value of the system symbol &RSRTYPE is set. If the system symbol &RSRTYPE is not specified, 191 is set.

Parameter specification example

INTERVAL INTVAL(30)                 +
         SYNCVAL(00)               

METRIC   LDEV
  
HDA      PREFIX(USERID)             +
         SN(11111,22222)

LDEVFILT DEVN(1000,2000:20FF)       +
         VOLSER(VOLA01,VOLB*)

SET      IODEVN(1000,1001,2000)     +
         RTYPE(128) 

The following is an example of how to specify a parameter when multiple subchannel sets are used.

INTERVAL INTVAL(30)                 +
         SYNCVAL(00)               

METRIC   LDEV
  
HDA      PREFIX(USERID)             +
         SN(11111,22222)

LDEVFILT DEVN(1000,2000:20FF,       +
              13000,14000:140FF)    +
         VOLSER(VOLA01,VOLB*)       +
         ACTSS(1)

SET      IODEVN(01000,01001,02000   +
                13000,13001,14000)  +
         RTYPE(128)    

The table below shows from which volumes information is collected when multiple subchannel sets are used, according to the specifications of the DEVN operand and the ACTSS operand.

Table. Values specified for DEVN and ACTSS and collection target volumes

Value specified for DEVN

Value specified for ACTSS

Collection target volume

DEVN(8000:8FFF)

ACTSS(1)

18000 to 18FFF#

DEVN(8000:8FFF)

--

08000 to 08FFF

18000 to 18FFF

28000 to 28FFF

38000 to 38FFF

DEVN(00000:03FFF)

DEVN(8000:8FFF)

ACTSS(1)

00000 to 03FFF

18000 to 18FFF#

DEVN(00000:03FFF)

DEVN(8000:8FFF)

--

00000 to 03FFF

08000 to 08FFF

18000 to 18FFF

28000 to 28FFF

38000 to 38FFF

Legend:

--: Do not specify.

#:

For example, if the volume 18005 does not exist in subchannel set 1, information about the volume 08005 in subchannel set 0 is to be collected.