RSSETENV

Mainframe Analytics Recorder User Guide

Version
10.1.x
Audience
anonymous
Part Number
MK-92HC226-08
ft:lastEdition
2026-01-30

Function

Sets the value of the following by using environment variables:

  • Output method of the event log

Command type

OS console command

Syntax

START RSSETENV, 
PARM='LOGPUT=[{LOGR|SAM}]'

Parameters

Multiple parameters can be specified for the maximum length that can be specified in the PARM parameter of the START command. If the same parameter is specified more than once, the value specified last takes effect.

LOGPUT=[LOGR|SAM]

Specify whether to use the system logger service when outputting the event log.

  • LOGR

    The event log is output using the system logger service.

  • SAM

    The event log is output to a sequential dataset without using the system logger service.

To remove the value of the environment variable LOGPUT, specify PARM='LOGPUT='.

Return codes

The following table lists and describes the return codes of the RSSETENV command.

Table. Return codes of the RSSETENV command.

Return codes

Meaning

0

Successfully completed.

8

The specified value is invalid. Processing was canceled.

12

Processing was canceled due to a system error (such as a GETMAIN error).

16

An internal error occurred.