RSDSPENV

Mainframe Analytics Recorder User Guide

Version
10.1.x
Audience
anonymous
Part Number
MK-92HC226-08
ft:lastEdition
2026-01-30

Function

Outputs the program product name and values of the MAR environment settings to the console.

Command type

OS console command

Syntax

START RSDSPENV 
[,PARM='[SUMMARY|DETAIL]']

Parameters

SUMMARY is assumed if the part from PARM onward was omitted.

SUMMARY

Displays the program product name and the information about whether to use the system logger service.

DETAIL

In addition to the content displayed when the SUMMARY parameter is specified, the environment variable values that were set by using the RSSETENV command, and system symbol values are displayed.

Return codes

The following table lists and describes the return codes of the RSDSPENV command.

Table. Return codes of the RSDSPENV command.

Return codes

Meaning

0

Successfully completed.

4

There is an error in the specified value. The command was executed assuming that SUMMARY is specified.

Execution examples

Execution example without the DETAIL parameter

START RSDSPENV
KTA403I mainframe analytics recorder
KTA400I Environment variables (vv.r.m-nn)
KTA401I Event log output method: LOGR

Execution example with the DETAIL parameter

START RSDSPENV,PARM='DETAIL'
KTA403I mainframe analytics recorder
KTA400I Environment variables (vv.r.m-nn)
KTA401I Event log output method: SAM
KTA402I LOGPUT  = SAM      (&YKLOGPT = "LOGR"    )