Function
Starts the MAR metric collection program.
Command type
OS console command
Syntax
START cataloged-procedure-name[.identifier-name] [,MEMBER=member-name] [,PARM=CHECK]
Parameters
- cataloged-procedure-name ~ <symbolic name consisting of 8 or fewer characters>
-
Name of the cataloged procedure for startup of the metric collection program that was registered in PROCLIB. For details on the START command, see the IBM manual MVS System Commands.
- identifier-name ~ <symbolic name consisting of 8 or fewer characters> <<startup-cataloged-procedure-name>>
-
Identifier name of cataloged procedures for startup of the metric collection program. To start multiple programs by using cataloged procedures for startup that have the same name, specify this parameter to distinguish each metric collection program. Specify the identifier name for the input operand of the STOP, CANCEL, or MODIFY command.
- member-name ~ <symbolic name consisting of 8 or fewer characters>
-
Member name of the dataset in which metric collection parameters were stored.
If you omit this parameter, the member name that was specified for the cataloged procedure for startup will be used. If you use the sample cataloged procedure for startup, the member name RSPRM00 will be used.