To collect event logs by using the system logger service, the settings for using the system logger service must be specified.
To use the DASD-only log stream for the system logger service, perform all sysplex setup procedures described in the IBM manual MVS Setting Up a Sysplex to set up the sysplex.
Care must be taken with the items shown in the following table during setup of the system logger service.
|
Item |
Required/optional |
Remarks |
|---|---|---|
|
Setting LOGR couple datasets |
Required |
-- |
|
Defining the SMS for the system logger service |
Optional |
Set this item when allocating staging datasets or log datasets to the SMS management volume. |
|
Defining a log stream |
Required |
-- |
|
Setting access privileges for system logger resources |
Optional |
Set this item when using the System Authorization Facility (SAF). |
|
Starting the system logger service |
Required |
-- |