KAPL10001-W
|
No parameter has been specified.
|
- Details
No directory to which the collected information will be output has been specified.
- Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10002-W
|
Too many parameters have been specified.
|
- Details
Four or more parameters have been specified.
- Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10003-W
|
The first parameter has not been set to a directory. Value = aa...aa
|
- Details
A value which is not a directory name is set for the first parameter. The first parameter must be a directory to which collected information will be output.
aa...aa: First parameter
- Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10004-W
|
The parameter contains an incorrect value. Value = aa...aa
|
- Details
The first parameter must be a directory. The second parameter must be -f.
aa...aa: Invalid parameter
- Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10005-W
|
The number of parameters is insufficient.
|
- Details
The -f parameter exists but the file for defining the information to be collected does not exist. The number of parameters is insufficient.
- Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10006-W
|
The file for defining the information to be collected does not exist, or cannot be read. Value = aa...aa
|
- Details
The file for defining the information to be collected does not exist, or the specified file exists but the permission to read the file is missing.
aa...aa: Name of the file for defining the information to be collected
- Action
Check whether the specified file for defining the information to be collected exists, and check whether you have access permission for the specified file.
|
KAPL10007-W
|
A directory has been specified in the third parameter. Value = aa...aa
|
- Details
A directory is specified for the -f parameter.
aa...aa: Third parameter
- Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then retry. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10008-W
|
You lack write permission for the specified directory. Value = aa...aa
|
- Details
You do not have write permission for the specified directory,
or the creation of a subdirectory of the specified directory failed.
aa...aa: first parameter
- Action
Check the following.
Check whether you have access permission for the specified directory.
Check whether the specified directory name is correct.
Check that the disk has sufficient unused capacity.
|
KAPL10009-W
|
The specified directory already exists. Do you want to overwrite it? [y/n]:
|
- Details
The specified directory already exists. To overwrite the directory, enter y. To cancel this operation, enter n.
- Action
The specified directory already exists. Enter y to overwrite the existing file. Enter n or press any other key to terminate the DLMgetras utility for collecting HDLM error information without executing it. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10010-W
|
A root directory has been specified. Line = aa...aa
|
- Details
The root "/" has been specified as a directory to be collected in the file for defining the information to be collected.
aa...aa: Line number of the file for defining information to be collected (decimal number)
- Action
Delete the coding of the root directory from the specified file. The displayed directory will be ignored and the DLMgetras utility for collecting HDLM error information will continue. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10011-W
|
More than one file or directory has been specified on one line. Line = aa...aa, Value = bb...bb
|
- Details
Two or more file names or directory names exist in the file for defining the information to be collected.
aa...aa: Line number of the file for defining information to be collected (decimal number)
bb...bb: Indicated contents in a line
- Action
After the DLMgetras utility for collecting HDLM error information terminates, check the contents of the file for defining the information to be collected. This file is shown in the message. If the contents of the file are incorrect, correct them and then try to collect error information again. The DLMgetras utility will ignore the specified file or directory and continue processing. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10012-W
|
The specified file or directory does not exist. Line = aa...aa, Value = bb...bb
|
- Details
The specified file or directory does not exist in the file for defining the where information is to be collected.
aa...aa: Line number of the file for defining which information to be collected (decimal (base-10) number)
bb...bb: Indicated contents of a line
- Action
After the DLMgetras utility for collecting HDLM error information terminates, check the contents of the file for defining the information to be collected. This file is shown in the message. If the contents of the file are incorrect, correct them and then try to collect error information again. The DLMgetras utility will ignore the specified file or directory and continue processing. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10013-W
|
You lack read permission for the specified file. Line = aa...aa, Value = bb...bb
|
- Details
You lack read permission for the specified file in the file for defining information to be collected.
aa...aa: Line number of the file for defining information to be collected (decimal number)
bb...bb: Indicated contents in a line
- Action
After the DLMgetras utility for collecting HDLM error information terminates, check the contents of the file for defining the information to be collected. This file is shown in the message. If the contents of the file are incorrect, correct them and then try to collect error information again. The DLMgetras will ignore the specified file and continue processing. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10014-W
|
You lack read permission for the specified directory. Line = aa...aa, Value = bb...bb
|
- Details
You lack read permission for the specified directory in the file for defining information to be collected.
aa...aa: Line number of the file for defining information to be collected (decimal number)
bb...bb: Indicated contents in a line
- Action
After the DLMgetras utility for collecting HDLM error information terminates, check the contents of the file for defining the information to be collected. This file is shown in the message. If the contents of the file are incorrect, correct them and then try to collect error information again. The DLMgetras will ignore the specified file and continue processing. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10015-W
|
The file format is invalid. Value = aa...aa
|
- Details
The file format is invalid. The file format in the file for defining information to be collected is not a text file.
aa...aa: Third parameter
- Action
After the DLMgetras utility for collecting HDLM error information terminates, check whether the file for defining the information to be collected is a text file. The file is shown in the message. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10016-W
|
The root directory has been specified in the first parameter.
|
- Details
The root directory has been specified in the first parameter. A root "/" cannot be specified in a directory to which collected information is output.
- Action
Check the parameters of the DLMgetras utility for collecting HDLM error information, and then re-execute. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10017-W
|
You lack privileges for executing the utility for collecting HDLM error information.
|
- Details
The DLMgetras utility for collecting HDLM error information must be executed by a user with root permissions.
- Action
Re-execute as a user with root permissions. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10020-I
|
The file has been obtained successfully. File = aa...aa, Collection time = bb...bb(GMT:bb...bb)
|
- Details
The file to be collected has been obtained.
aa...aa: Collected file name
bb...bb: Year/month/day hour:minute:second
- Action
None.
|
KAPL10021-I
|
Processing terminated before completion because a signal was received.
|
- Details
The process has been terminated by an operation such as Ctrl + c.
- Action
The utility for collecting HDLM error information terminated before completion.
If the directory is unnecessary, delete directory. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10022-I
|
The utility for collecting HDLM error information completed normally.
|
- Details
Error information has been collected.
- Action
None. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10030-I
|
A user terminated the utility for collecting HDLM error information.
|
- Details
Processing of the DLMgetras utility for collecting HDLM error information has been terminated because the user replied to the confirmation with an n response.
- Action
None. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10031-W
|
The entered value is invalid. Continue operation? [y/n]:
|
- Details
A value other than y or n has been entered for a [y/n] request. Enter y or n.
- Action
Enter y or n.
|
KAPL10032-W
|
The entered value is invalid. The utility for collecting HDLM error information stops.
|
- Details
Processing of the DLMgetras utility for collecting HDLM error information will terminate because an invalid response was sent three times in a row to a request.
- Action
Re-execute the DLMgetras utility. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10033-W
|
The file does not exist. Filename = aa...aa
|
- Details
The file to collect does not exist.
aa...aa: Name of file to collect
- Action
None.
|
KAPL10034-E
|
The file could not be copied. Filename = aa...aa, Details = bb...bb
|
- Details
Execution of the cp command failed.
aa...aa: Name of the file you tried to copy
bb...bb: cp command output message
- Action
An error occurred while the collected files were being copied. The environment, in which a user executed the command, might be wrong. Check the system configuration.
|
KAPL10035-E
|
An attempt to archive the error information failed. Details = aa...aa
|
- Details
Execution of the tar command failed.
aa...aa: tar command output message
- Action
See the details in the message, and then remove the cause of the error. For information about the error, collect the archive in the output directory specified at the time of execution, and then contact your HDLM vendor or your maintenance company if you have a maintenance contract for HDLM.
|
KAPL10036-E
|
An attempt to compress the error information failed. Details = aa...aa
|
- Details
Execution of the gzip command failed.
aa...aa: gzip command output message
- Action
See the details in the message, and then remove the cause of the error. For information about the error, collect the archive in the output directory specified at the time of execution, and then contact your HDLM vendor or the maintenance company if you have a maintenance contract for HDLM.
|
KAPL10037-W
|
The file does not exist or does not have executable permissions. Filename = aa...aa
|
- Details
There is no output file, or the user does not have execution permission.
aa...aa: file name
- Action
Make sure the specified file exists and the user has execution permission.
|
KAPL10049-I
|
Error information collection command = aa...aa, Return value = bb...bb, Execution time = cc...cc
|
- Details
aa...aa: Executed command
bb...bb: Return value of the executed command
cc...cc: Year (4 digits)/month/day hour:minute:second
- Action
None.
|
KAPL10050-I
|
The utility for collecting HDLM error information started. Start time = aa...aa (GMT aa...aa)
|
- Details
aa...aa: Year (4 digits)/month/day hour:minute:second
- Action
None.
|
KAPL10301-I
|
/sbin/dlmcfgmgr started: aa...aa
|
- Details
The HDLM-configuration definition utility (dlmcfgmgr) has started.
aa...aa: date and time (for example, Fri Aug 23 19 : 12 : 50 2004)
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10302-I
|
/sbin/dlmcfgmgr completed normally.
|
- Details
The HDLM-configuration definition utility (dlmcfgmgr) has completed successfully.
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10305-E
|
A special file could not be created. Filename = aa...aa. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
A logical device file for an HDLM device cannot be created.
aa...aa: Logical device file name of HDLM device
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10306-W
|
The configuration definition file is invalid. Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
The configuration definition file (/etc/opt/DynamicLinkManager/.dlmfdrv.conf) is invalid.
- Action
/etc/opt/DynamicLinkManager/.dlmfdrv.conf to an alias name and restart the host. The logical device file name of the HDLM device might be changed, so that after the host restarts, check the logical device file name. If the logical device file name was changed, modify the path to the upper-level program.
|
KAPL10308-W
|
The configuration definition file could not be created. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
The configuration definition file (/etc/opt/DynamicLinkManager/.dlmfdrv.conf) could not be created.
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10309-W
|
The HDLM management-target disk does not exist. Check the system configuration.
|
- Details
The HDLM management-target device does not exist.
- Action
Check the system configuration.
|
KAPL10312-I
|
HDLM has created an HDLM device special file. Device = aa...aa
|
- Details
A logical device file for an HDLM device has been created.
aa...aa: Logical device file name of HDLM device
- Action
None.
|
KAPL10313-I
|
HDLM has deleted an HDLM device special file. Device = aa...aa
|
- Details
A logical device file for an HDLM device has been deleted.
aa...aa: Logical device file name of HDLM device
- Action
None.
|
KAPL10314-I
|
HDLM has updated an HDLM device special file. Device = aa...aa
|
- Details
A logical device file for an HDLM device has been updated.
aa...aa: Logical device file name of HDLM device
- Action
None.
|
KAPL10316-E
|
Could not allocate memory. Size = aa...aa. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
Securing of memory failed.
aa...aa: Target memory size (decimal number)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10318-E
|
An internal error occurred in the HDLM-configuration definition utility (dlmcfgmgr). Code = aa...aa Errno = bb...bb cc...cc. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An internal error occurred in the HDLM-configuration definition utility (dlmcfgmgr).
aa...aa: Line number in which the error occurred (decimal number)
bb...bb: Error number (errno) (decimal number)
cc...cc: Detailed information (optional)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10319-W
|
usage: /sbin/dlmcfgmgr [-s]
{-r
|-o {special-file-name ... | all}
|-i {special-file-name ... | all}
|-v [-udev]
|-u {special-file-name ... | all}
|-extenddev {hdlm-special-file... | all}
|-logfs [log-file-size]}
|
- Details
Since the parameter of the HDLM-configuration definition utility (dlmcfgmgr) was inaccurate, execution of the dlmcfgmgr utility failed. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
- Action
Specify the correct options, and then re-execute the dlmcfgmgr utility.
|
KAPL10320-E
|
The file format is invalid. File name = aa...aa. Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
The file format is invalid.
aa...aa: file name
- Action
Re-execute the HDLM-configuration definition utility (dlmcfgmgr). If the same message is output, execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or maintenance company if you have a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10321-W
|
The specified HDLM device is invalid. Device = aa...aa. Specify a valid logical device file name of an HDLM device, and then execute the dlmcfgmgr utility.
|
- Details
Executing the HDLM-configuration definition utility (dlmcfgmgr) failed because the logical device file name of the HDLM device was incorrect.
aa...aa: Logical device file name of HDLM device
- Action
Specify a correct logical device file name of an HDLM device, and then re-execute the dlmcfgmgr utility. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10322-E
|
A file that defines HDLM-unmanaged disks could not be created. File name = aa...aa, Errno = bb...bb. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
Execution of the HDLM-configuration definition utility (dlmcfgmgr) failed because an exclusion disk definition file (aa...aa) could not be created.
aa...aa: File name
bb...bb: Error number (decimal number)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10323-E
|
The registration of the block device driver for HDLM failed. All dynamic major numbers are exhausted. Unload (remove from the kernel) an unnecessary driver, and then execute the dlmcfgmgr utility again.
|
- Details
Registration of the block device driver of HDLM failed because all dynamic major numbers were used.
- Action
Unload (remove from the kernel) any unnecessary driver, and then re-execute the HDLM-configuration definition utility (dlmcfgmgr). For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10324-I
|
The device configuration of the system has changed. Device = aa...aa
|
- Details
The device composition of a system to a device (aa...aa) was changed.
aa...aa: HDLM device name
- Action
None.
|
KAPL10325-E
|
A regular expression cannot be established. The files will not be deleted. Errno = aa...aa. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An HDLM device could not be deleted because the device could not be found by using a regular expression.
aa...aa: Error number (decimal number)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10326-E
|
You lack permission for executing the HDLM-configuration definition utility. Execute the dlmcfgmgr utility as a user with root permission.
|
- Details
The current user does not have authority to execute the HDLM-configuration definition utility (dlmcfgmgr).
- Action
Re-execute the dlmcfgmgr utility as a user with root permission. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10327-W
|
The entered value is invalid.
|
- Details
The value input into the execution check message of the HDLM-configuration definition utility (dlmcfgmgr) is invalid.
- Action
Enter the correct y/n value after the KAPL10339-I message is output. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10328-E
|
The entered value is invalid. The HDLM-configuration definition utility processing will now stop. Execute the HDLM-configuration definition utility again.
|
- Details
An invalid value was entered 3 or more times for the message confirming the execution of the HDLM-configuration definition utility (dlmcfgmgr). Processing is interrupted.
- Action
Re-execute the dlmcfgmgr utility. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10329-E
|
A file could not be opened. File name = aa...aa, Errno = bb...bb. Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
The file could not be opened.
aa...aa: File name
bb...bb: Error number (decimal number)
- Action
Confirm the existence of the file. If there is no problem, and then execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10330-E
|
A symbolic link cannot be created. File name = aa...aa, Errno = bb...bb. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An attempt to create a symbolic link has failed.
aa...aa: File name
bb...bb: Error number (decimal number)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10331-E
|
The registering of the block device driver for HDLM failed. Errno = aa...aa. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An attempt to register the block device driver of HDLM has failed.
aa...aa: Error number (decimal number)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10332-E
|
The registering of the partition information for HDLM device(s) failed. Errno = aa...aa. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An attempt to register the partition information on HDLM has failed.
aa...aa: Error number (decimal number)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10333-E
|
An internal error occurred in the file operation. File name = aa...aa. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An internal error occurred during file operation.
aa...aa: File name
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10334-E
|
Ioctl aa...aa failed with errno = bb...bb. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An attempt to issue an IOCTL call has failed.
aa...aa: IOCTL name
bb...bb: Error number (decimal number)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10335-E
|
A directory cannot be created. Directory = aa...aa, Errno = bb...bb. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An attempt to create a directory has failed.
aa...aa: Directory name
bb...bb: Error number (decimal number)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10336-W
|
A file cannot be deleted. File name = aa...aa. Manually delete the file aa...aa
|
- Details
An attempt to delete a file has failed.
aa...aa: File name
- Action
Delete the file shown in File name.
|
KAPL10337-W
|
A special device exists with a different major number. The device will now be unlinked. Device = aa...aa
|
- Details
The HDLM device indicated by aa...aa was deleted because the major number for its logical device file is invalid.
aa...aa: Logical device file name of the HDLM device
- Action
None.
|
KAPL10338-W
|
A directory cannot be deleted. Directory = aa...aa. Manually delete the directory aa...aa
|
- Details
An attempt to delete a directory has failed.
aa...aa: Directory name
- Action
Delete the directory shown in Directory.
|
KAPL10339-I
|
This operation will change the configuration of HDLM devices.
Do you want to continue? [y/n]:
|
- Details
This message checks whether you want to change the configuration definition of an HDLM device.
- Action
Enter y to continue. Enter n to cancel.
|
KAPL10340-E
|
Several processes failed. See the aa...aa file. Check the message output before this message.
|
- Details
Some processes in the execution of the HDLM-configuration definition utility (dlmcfgmgr) have failed. Check the file aa...aa.
aa...aa: File name
- Action
See the /var/opt/DynamicLinkManager/log/dlmcfgmgr1.log file and check the message output before this message. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10341-I
|
The HDLM device configurations have been changed.
|
- Details
The configuration of an HDLM device was changed by execution of the HDLM-configuration definition utility (dlmcfgmgr).
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10343-I
|
HDLM has detected and registered a new HDLM device. HDLM device = aa...aa
|
- Details
By executing the HDLM-configuration definition utility (dlmcfgmgr), a new HDLM device has been detected and registered into the HDLM device configuration definition.
aa...aa: Logical device file name of HDLM device
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10344-I
|
HDLM has detected and registered a new path to an already registered HDLM device. HDLM device = aa...aa, Device = bb...bb (Host: cc...cc Channel: 0 ID: dd...dd Lun: ee...ee)
|
- Details
By executing the HDLM-configuration definition utility (dlmcfgmgr), a newly detected path has been added to the registered HDLM device.
aa...aa: HDLM device name
bb...bb: SCSI device name
cc...cc: Host ID (decimal number)
Channel: Channel ID (fixed value: 0) (decimal number)
dd...dd: Target ID (decimal number)
ee...ee: LUN (decimal number)
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10345-I
|
HDLM has unregistered the existing path to an HDLM device. HDLM device = aa...aa, Device = bb...bb (Host: cc...cc Channel: 0 ID: dd...dd Lun: ee...ee)
|
- Details
By executing the HDLM-configuration definition utility (dlmcfgmgr), the existing path has been unregistered from the registered HDLM device.
aa...aa: HDLM device name
bb...bb: SCSI device name
cc...cc: Host ID (decimal number)
Channel: Channel ID (fixed value: 0) (decimal number)
dd...dd: Target ID (decimal number)
ee...ee: LUN (decimal number)
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10346-I
|
HDLM has unregistered an existing HDLM device. HDLM device = aa...aa
|
- Details
By executing the HDLM-configuration definition utility (dlmcfgmgr), the registered HDLM device has been unregistered.
aa...aa: Logical device file name of HDLM device
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10347-I
|
The HDLM device is no longer under management. HDLM device = aa...aa
|
- Details
By executing the HDLM-configuration definition utility (dlmcfgmgr), the HDLM device has been removed from HDLM management.
aa...aa: Logical device file name of HDLM device
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10348-I
|
The HDLM device is now under management. HDLM device = aa...aa
|
- Details
By executing the HDLM-configuration definition utility (dlmcfgmgr), the HDLM device has been placed under HDLM management.
aa...aa: Logical device file name of HDLM device
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10349-I
|
HDLM will remove unavailable paths or devices. HDLM device = aa...aa
|
- Details
By executing the HDLM-configuration definition utility (dlmcfgmgr), a path and a logical device file of an HDLM device has been deleted.
aa...aa: Logical device file name of HDLM device
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10350-E
|
The HDLM driver(s) is not loaded. Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
An attempt to execute the HDLM-configuration definition utility (dlmcfgmgr) failed because the HDLM driver was not loaded.
- Action
Carry out the following process:
Execute the following command to load the HDLM driver
# /opt/DynamicLinkManager/bin/dlminsadrv
# modprobe sddlmfdrv
Re-execute the dlmcfgmgr utility.
For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10351-E
|
The specified HDLM-configuration definition utility is invalid. Operation name = aa...aa, Parameter = bb...bb
|
- Details
An attempt to execute the HDLM-configuration definition utility (dlmcfgmgr) failed because the specified operation name (aa...aa:) or parameter (bb...bb) was invalid.
aa...aa: Operation name
bb...bb: Parameter
- Action
Confirm that the operation name and parameter are correct, and then re-execute the dlmcfgmgr utility. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10352-W
|
The HDLM device is in use. HDLM device = aa...aa. Stop the application using the HDLM device, unmount the HDLM device being mounted, and then execute the dlmcfgmgr utility again.
|
- Details
An attempt to execute the HDLM-configuration definition utility (dlmcfgmgr) failed because the specified HDLM device (aa...aa) was using it.
aa...aa: HDLM device name
- Action
Stop the application using the HDLM device, unmount the HDLM device being mounted, and then re-execute the dlmcfgmgr utility. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10353-W
|
An error occurred while a backup of the HDLM files was being acquired. File name = aa...aa. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An error occurred during acquisition of the HDLM file (aa...aa) backup.
aa...aa: File name
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10354-E
|
An attempt to unregister a block device driver for HDLM failed. Stop the application using the HDLM device, and unmount the mounting HDLM device, and then execute the dlmcfgmgr utility again.
|
- Details
An attempt to execute the HDLM-configuration definition utility (dlmcfgmgr) failed because registration of an HDLM block device driver could not be released.
- Action
Stop the application for using HDLM device, and unmount the mounting HDLM device, and re-execute the dlmcfgmgr utility. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10355-E
|
An attempt to unregister partition information for the HDLM device(s) failed. Stop the application using the HDLM device, and unmount the mounting HDLM device, and then execute the dlmcfgmgr utility again.
|
- Details
An attempt to execute the HDLM-configuration definition utility (dlmcfgmgr) failed because registration of the partition information on an HDLM device could not be released.
- Action
Stop the application for using HDLM device, and unmount the mounting HDLM device, and re-execute the dlmcfgmgr utility. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10356-E
|
An unused major number could not be released. Major number = aa...aa. Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
An attempt to release an intact major number (aa...aa) has failed.
aa...aa: Major number (decimal number)
- Action
Restart the host. If the host does not recover, execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10357-E
|
The maximum number of HDLM device files has been reached. Maximum number = aa...aa. Modify the configuration of the HDLM device to reduce the number of HDLM devices used, and then execute the dlmcfgmgr utility again.
|
- Details
An attempt to execute the HDLM-configuration definition utility (dlmcfgmgr) failed because the maximum number of logical device files has been created.
aa...aa: Maximum number of created logical device files of an HDLM device (decimal number)
- Action
Revise the configuration of the HDLM device to reduce the number of HDLM devices used, and then re-execute the dlmcfgmgr utility. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10358-E
|
The device name is too long. Maximum length = aa...aa. Check that the logical device file name of the HDLM device is correct, and then execute the dlmcfgmgr utility again.
|
- Details
An attempt to execute the HDLM-configuration definition utility (dlmcfgmgr) failed because the name of the logical device file is too long.
aa...aa: Maximum length of characters for a logical device file name (decimal)
- Action
Check that the logical device file name of the HDLM device is correct, and then re-execute the dlmcfgmgr utility. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10359-E
|
Multiple instances of the HDLM-configuration definition utility cannot be executed concurrently. Wait until the running dlmcfgmgr utility ends, and then try the dlmcfgmgr utility again.
|
- Details
An attempt to execute dlmcfgmgr failed because two or more instances of dlmcfgmgr were executed simultaneously.
- Action
Wait until the running HDLM-configuration definition utility (dlmcfgmgr) ends, and then re-execute the HDLM-configuration definition utility (dlmcfgmgr). For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10360-I
|
HDLM has activated a path for an HDLM device. HDLM device = aa...aa, Device = bb...bb (Host: cc...cc Channel: 0 ID: dd...dd Lun: ee...ee)
|
- Details
By executing the HDLM-configuration definition utility (dlmcfgmgr), the path to the HDLM device has been made active.
aa...aa: HDLM device name
bb...bb: SCSI device name
cc...cc: Host ID (decimal number)
Channel: Channel ID (fixed value: 0) (decimal number)
dd...dd: Target ID (decimal number)
ee...ee: LUN (decimal number)
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10361-I
|
HDLM has deactivated a path for the HDLM device. HDLM device = aa...aa, Device = bb...bb (Host: cc...cc Channel: 0 ID: dd...dd Lun: ee...ee)
|
- Details
By executing the HDLM-configuration definition utility (dlmcfgmgr), the path to the HDLM device has been made inactive.
aa...aa: HDLM device name
bb...bb: SCSI device name
cc...cc: Host ID (decimal number)
Channel: Channel ID (fixed value: 0) (decimal number)
dd...dd: Target ID (decimal number)
ee...ee: LUN (decimal number)
- Action
None. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10362-W
|
HDLM has detected an active path that cannot be deleted. HDLM device = aa...aa, Device = bb...bb (Host: cc...cc Channel: 0 ID: dd...dd Lun: ee...ee). Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
An attempt to execute the HDLM-configuration definition utility (dlmcfgmgr) failed because a path to the specified HDLM device was being used.
aa...aa: HDLM device name
bb...bb: SCSI device name
cc...cc: Host ID (decimal number)
Channel: Channel ID (fixed value: 0) (decimal number)
dd...dd: Target ID (decimal number)
ee...ee: LUN (decimal number)
- Action
Stop the application that uses the HDLM device, unmount the HDLM device being mounted, and then re-execute the dlmcfgmgr utility. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10363-W
|
A data mismatch was found. HDLM device = aa...aa. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
When HDLM configuration Definition Utility (dlmcfgmgr) was executed, a mismatch of HDLM device configuration information was detected.
aa...aa: Logical device file name of HDLM device
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10364-I
|
The LDEV for an HDLM device has changed. HDLM will now change the configuration. HDLM device = aa...aa
|
- Details
The configuration has been modified because an LDEV corresponding to an HDLM device was changed.
aa...aa: Logical device file name of an HDLM device
- Action
None.
|
KAPL10365-W
|
The LDEV for an HDLM device has changed. The processing for that HDLM device will be cancelled. HDLM device = aa...aa. Execute the HDLM-configuration definition utility (dlmcfgmgr) with the -v option, and then check the configuration of the HDLM device.
|
- Details
The processing for the HDLM device was interrupted because an LDEV corresponding to an HDLM device was changed.
aa...aa: The logical device file name of the HDLM device
- Action
Execute the HDLM-configuration definition utility (dlmcfgmgr) with the -v option, and then check the configuration of the HDLM device. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10366-I
|
Unsupported SCSI device was found. Device = aa...aa
|
- Details
The SCSI device output in this message is not supported.
aa...aa: Logical device file name of HDLM device
- Action
None.
|
KAPL10641-I
|
Reservation Key will now be cleared. Is this OK? [y/n]:
|
- Details
Enter y to clear and n to not clear the reservation key.
- Action
None.
|
KAPL10642-I
|
Reservation Key of aa...aa was cleared.
|
- Details
The reservation key has been cleared.
aa...aa: Logical device file name for the HDLM management-target device
- Action
None.
|
KAPL10643-W
|
A necessary parameter is not specified.
|
- Details
A parameter is not specified for the dlmpr utility.
- Action
Execute the dlmpr -h utility to check the parameter, and then retry execution. For details on the dlmpr utility, see dlmpr utility for clearing HDLM persistent reservation.
|
KAPL10644-W
|
The specified parameters cannot be specified at the same time. parameter = aa...aa
|
- Details
The specified parameters cannot be specified for the dlmpr utility at the same time.
aa...aa: Specified parameter
- Action
Execute the dlmpr -h utility to check the parameter, and then retry execution. For details on the dlmpr utility, see dlmpr utility for clearing HDLM persistent reservation.
|
KAPL10645-W
|
A parameter value is invalid. parameter = aa...aa
|
- Details
An invalid parameter value has been specified for the dlmpr utility.
aa...aa: Specified parameter
- Action
Specify the correct value for the parameter, and then retry. For details on the dlmpr utility, see dlmpr utility for clearing HDLM persistent reservation.
|
KAPL10646-W
|
A parameter is invalid. parameter = aa...aa
|
- Details
An invalid parameter has been specified for the dlmpr utility.
aa...aa: Specified parameter
- Action
Execute help of the dlmpr utility to check the parameters that can be specified, and then retry. For details on the dlmpr utility, see dlmpr utility for clearing HDLM persistent reservation.
|
KAPL10648-E
|
An internal error occurred in the dlmpr utility. Error Code = aa...aa
|
- Details
An error not caused by the user has occurred in the dlmpr utility.
aa...aa: Error number (character string)
- Action
When the error code is 1: Make sure that there is sufficient memory.
When the error code is 2: Contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
When the error code is 4 or 5: Make sure that the SCSI device file permissions permit reading and writing.
For details on the dlmpr utility, see dlmpr utility for clearing HDLM persistent reservation.
|
KAPL10649-E
|
aa...aa : An attempt to perform Reservation Key clear processing has failed.
|
- Details
An attempt to perform reservation key clear processing has failed.
aa...aa: HDLM device (dlmfdrvn)
- Action
Contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
|
KAPL10650-I
|
aa...aa : NO RESERVATION
|
- Details
A LU has not been reserved.
aa...aa: HDLM device (dlmfdrvn)
- Action
None.
|
KAPL10651-I
|
The user terminated the operation.
|
- Details
The dlmpr utility has been terminated because n was sent to a request.
- Action
None. For details on the dlmpr utility, see dlmpr utility for clearing HDLM persistent reservation.
|
KAPL10652-E
|
The entered value is invalid. The operation stops.
|
- Details
An invalid response was sent three times consecutively to a request.
- Action
Re-execute the dlmpr utility. For details on the dlmpr utility, see dlmpr utility for clearing HDLM persistent reservation.
|
KAPL10653-W
|
The entered value is invalid. Please re-enter it [y/n]:
|
- Details
A value other than y or n has been entered for a [y/n] request.
- Action
Enter y or n.
|
KAPL10665-I
|
The dlmpr utility completed.
|
- Details
The dlmpr utility completed normally.
- Action
None. For details on the dlmpr utility, see dlmpr utility for clearing HDLM persistent reservation.
|
KAPL10920-W
|
Processing for HDLM Config Manager interrupted. Execute the HDLM-configuration definition utility (dlmcfgmgr) again.
|
- Details
Processing of the HDLM-configuration definition utility (dlmcfgmgr) was interrupted.
- Action
Please re-execute the HDLM-configuration definition utility (dlmcfgmgr).
For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10922-E
|
The version of the kernel supported by the installed HDLM does not match the currently running kernel version. Install the HDLM software that supports this kernel version.
|
- Details
The version of the kernel to which installed HDLM has adjusted and the kernel that is running now is not corresponding. There is a possibility of installing the package of the kernel after installing HDLM.
- Action
Install HDLM that adjusts to the kernel that is running now.
|
KAPL10923-E
|
The HDLM file is invalid. File name = aa...aa. Reinstall the HDLM software.
|
- Details
A file necessary for processing HDLM cannot be found. Alternatively, the content of a file is invalid.
aa...aa: Name of file where error was detected.
- Action
Reinstall an HDLM.
|
KAPL10934-W
|
A file could not be opened. File name = /etc/opt/DynamicLinkManager/hdlm_utillog.conf, Errno = aa...aa. Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
An attempt to open the settings file for the HDLM utility log (/etc/opt/DynamicLinkManager/hdlm_utillog.conf) has failed.A maximum log file size of 1024 KB will be assumed, and the processing of the dlmcfgmgr utility will continue.
aa...aa: Error number (decimal number)
- Action
Make sure that the file exist. If the file is normal, execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10935-W
|
An internal error occurred in the file operation. File name = /etc/opt/DynamicLinkManager/hdlm_utillog.conf. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
An internal error occurred during operations of the settings file for the HDLM utility log (/etc/opt/DynamicLinkManager/hdlm_utillog.conf). A maximum log file size of 1024 KB will be assumed, and the processing of the dlmcfgmgr utility will continue.
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10936-W
|
The file format is invalid. File name = /etc/opt/DynamicLinkManager/hdlm_utillog.conf. Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
The format of the settings file for the HDLM utility log (/etc/opt/DynamicLinkManager/hdlm_utillog.conf) is invalid.A maximum log file size of 1024 KB will be assumed, and the processing of the dlmcfgmgr utility will continue.
- Action
Execute the dlmcfgmgr utility with the -logfs parameter specified. If the error occurs again, /etc/opt/DynamicLinkManager/hdlm_utillog.conf which is not a regular file might exist. Delete /etc/opt/DynamicLinkManager/hdlm_utillog.conf and then execute the dlmcfgmgr utility again. For details on the dlmcfgmgr utility, see dlmcfgmgr utility for managing the HDLM configuration.
|
KAPL10937-W
|
The maximum number of paths was exceeded. Revise the configuration so that the number of paths is less than, or the same as, the maximum number. Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
The number of paths in the entire system exceeded the maximum number of paths supported in HDLM. Review and, if necessary, revise the configuration.
- Action
The maximum number of paths supported in HDLM has been exceeded. Review and, if necessary, revise the number of paths in the entire system. For details on the number of paths supported in HDLM, see Number of LUs and paths that are supported in HDLM.
|
KAPL10938-I
|
dlmcfgmgr Log File Size(KB) : aa...aa
|
- Details
aa...aa: The setup value or default value of dlmcfgmgr Log File Size.
- Action
None.
|
KAPL10939-W
|
An error occurred during processing to read a file. File name = aa...aa
|
- Details
An error occurred during processing to read a file.
aa...aa: File name
- Action
Follow the instructions in the message that was output before this message.
|
KAPL10940-W
|
The maximum wait time has been reached. Maximum wait time = aa...aa, Checking interval = bb...bb
|
- Details
The maximum wait time has been reached.
aa...aa: Maximum wait time
bb...bb: Checking interval
- Action
Perform the following action if you use a boot disk environment where a SCSI device is used.
If the path status is Offline(E) or Online(E) because recognition of the SCSI device is delayed when the OS starts, increase the value of scsicheckmax in the /etc/opt/DynamicLinkManager/hdlm.conf file to a value that is appropriate for your environment.
Perform the following action for a boot disk environment where an HDLM device is used.
Confirm that the configuration for HDLM devices is correct.
If it is not correct, execute the DLMgetras utility to collect HDLM error information, and then contact your HDLM vendor, or the maintenance company if you have a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10941-W
|
The file could not be opened. File name = aa...aa, Errno = bb...bb
|
- Details
The file could not be opened.
aa...aa: File name
bb...bb: Errno
- Action
Confirm that the configuration for HDLM devices is correct.
If it is not correct, execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10942-W
|
Memory could not be allocated. Size = aa...aa, Errno = bb...bb
|
- Details
Memory could not be allocated.
aa...aa: Size
bb...bb: Errno
- Action
Confirm that the configuration for HDLM devices is correct.
If it is not correct, execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10943-W
|
An error occurred during processing to read a file in the (aa...aa) function. File name = bb...bb, Errno = cc...cc
|
- Details
An error occurred during processing to read a file in the (aa...aa) function.
bb...bb: File name
cc...cc: Errno
- Action
Confirm that the configuration for HDLM devices is correct.
If it is not correct, execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10944-I
|
Checking will now start. Checking interval = aa...aa, Check count = bb...bb, Maximum wait time = cc...cc
|
- Details
Checking will now start.
aa...aa: Checking interval
bb...bb: Check count
cc...cc: Maximum wait time
- Action
None.
|
KAPL10948-W
|
An invalid entry is registered in the file. File name = aa...aa
|
- Details
An invalid entry is registered in the file.
aa...aa: File name
- Action
Edit the /etc/opt/DynamicLinkManager/hdlm.conf file as follows, and then restart the host.
For FC-SAN:
iscsi_boot=n
For IP-SAN:
iscsi_boot=y
|
KAPL10949-E
|
A necessary file was not found. File name = aa...aa
|
- Details
A necessary file was not found.
aa...aa: File name
- Action
Reinstall an HDLM.
|
KAPL10950-E
|
An error occurred during creation of an HDLM temporary file. File name = aa...aa. Refer to the Messages section of the HDLM User's Guide for instructions to correct this problem.
|
- Details
An error occurred during creation of an HDLM temporary file.
aa...aa: File name
- Action
Confirm that the root directory (/) has enough unused capacity.
If it has enough unused capacity, execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10959-E
|
The configuration definition file is invalid. Error Code = aa...aa. Execute the DLMgetras utility to collect error information, and then contact your vendor or maintenance company.
|
- Details
The contents of the configuration definition file (/etc/opt/DynamicLinkManager/.dlmfdrv.conf) are invalid.
aa...aa: Internal code (decimal (base-10) number)
- Action
Execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM.
For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|
KAPL10960-I
|
The LU capacity does not need to be updated because the LU capacity is up to date. Device = aa...aa
|
- Details
The LU capacity does not need to be updated because the LU capacity is up to date.
aa...aa: Target device file
- Action
None.
|
KAPL10961-I
|
The LU capacity was updated. Device = aa...aa
|
- Details
The LU capacity was updated.
aa...aa: Target device file
- Action
None.
|
KAPL10962-E
|
The LU capacity of a managed HDLM device cannot be decreased. Device = aa...aa
|
- Details
The LU capacity of a managed HDLM device cannot be decreased.
aa...aa: Target device file
- Action
For the HDLM device displayed in the message, remove it from HDLM management and then put it under HDLM management again.
|
KAPL10963-E
|
Failed to update the LU capacity. Device = aa...aa
|
- Details
Failed to update the LU capacity.
aa...aa: Target device file
- Action
The following conditions apply to the HDLM device corresponding to the HDLM device file that is output to a message. Verify that all of the following conditions are met:
The HDLM device file exists.
All of the paths of the HDLM device are online.
All of the HDLM device paths (SCSI devices) have the same LU capacity.
Verify that all conditions are met, and then retry the command. If an error still occurs, even though all conditions are met, execute the DLMgetras utility for collecting HDLM error information, and then contact your HDLM vendor or the maintenance company if there is a maintenance contract for HDLM. For details on the DLMgetras utility, see DLMgetras utility for collecting HDLM error information.
|