Migrating volumes with CCI

Volume Migration User Guide for VSP One Block 85

Version
10.5.x
File Size
100 KB
Audience
anonymous
Part Number
MK-26VSP1B039-01
ft:lastEdition
2026-03-06

In this example, group1 represents the group name in the CCI configuration definition file, and pair1 represents the name of the volume whose pair is the target volume of the operation.

CAUTION:
If any of the following operations is performed on a Volume Migration source volume during migration, the volume migration process stops:
  • ShadowImage operation that changes the volume status to COPY(SP) or PSUS(SP)
  • ShadowImage for Mainframe operation that changes the volume status to SP-Pend/TRANS or V-Split/SUSPVS
  • TrueCopy operation that changes the volume status to something other than PSUS/PSUE/PAIR
  • TrueCopy for Mainframe operation that changes the volume status to something other than Suspended
  • Universal Replicator operation that changes the volume status to something other than PSUS
  • Universal Replicator for Mainframe operation that changes the volume status to something other than Suspended
  • Compatible XRC operation
  • Concurrent Copy operation
  • The volumes must meet all requirements as source and target volume candidates.
  1. Start CCI.
  2. Type the following command for a SMPL pair to start volume migration:

    paircreate -g group1 -d pair1 -m cc -vl

    When volume migration starts, the status of the pair changes to COPY.

  3. Type the following command to check the status of the pair:

    pairdisplay –g group1 –d pair1 -fcex

    When volume migration completes, the status of the pair changes to PSUS. If volume migration fails, the status of the pair changes to PSUE.

  4. After the pair status is changed to PSUS or PSUE, type the following command to delete the pair (change the pair status back to SMPL):

    pairsplit –S –g group1 –d pair1

    Note:
    • If the migration fails (the status of the pair becomes PSUE) in step 3, repeat steps 2 to 4. When the alert message is displayed, check the alert message and recover the failure, and then repeat steps 2 to 4. If you are unable to change the pair status back to SMPL, contact the service engineer.
    • Entering the pairsplit -S command during volume migration interrupts volume migration.