The following table lists parameters that can be set for CCI options and indicates the range for each parameter.

Parameter

Range

Mirror ID (MU#)

0

CTG ID

0 to 127 for VSP One B20 series, 0 to 255 for VSP One B85

Path group ID

0 to 255

Maximum initial copy activities

1 to 512

Maximum initial copy activities per CU

1 to 16

Blocked path monitoring time

2 to 200 seconds

(VSP One B20 series) The range is 2 to 45 seconds when the DKCMAIN firmware version is earlier than A3-04-21-xx/xx.

(VSP One B20 series) The same range of values is used for TrueCopy, Universal Replicator, and global-active device.

Blocked path SIM monitoring time

2 to 200 seconds

(VSP One B20 series) The range is 2 to 100 seconds when the DKCMAIN firmware version is earlier than A3-04-21-xx/xx.