SSB2 error codes when SSB1 = 2E31, B901, B90A, B90B, B912, D004

True Copy for Mainframe User Guide for VSP One Block 85

Version
10.5.x
FileSize
2745 KB
Audience
anonymous
Part Number
MK-26VSP1B036-02
ft:lastEdition
2026-06-23
Product
SVOS

Error code (SSB2)

Description

47A3

The pair cannot be split because of one of the following conditions:

  • Write access permitted in the S-VOL is unsupported.
  • Swap Suspend is unsupported.

47A6

The Swap Resync operation was received but failed because the status does not allow swapping.

47BA

The pair cannot be created because the specified P-VOL is one of the following:

  • Used as an SIz S-VOL.
  • Intervention-required or protected.

4A5C

The pair cannot be created because TCz asynchronous is not supported.

4AB5

The pair cannot be resynchronized because the specified volume is an MTIR pair.

4AB6

The pair cannot be suspended because the specified volume is an MTIR pair.

4AE6

The pair cannot be created because the specified P-VOL is already in PPRC multi-target configuration.

4AE7

The pair cannot be created because the specified volume is already a TCz pair.

4AE8

The operation failed because the specified parameter is not correct.

4AF3

The pair cannot be split because Soft Fence is set for the specified volume.

4AF4

The pair cannot be deleted because Soft Fence is set for the specified volume.

4AF5

The pair cannot be created or resynchronized because Soft Fence is set for the specified volume.

4B04

The pair cannot be created because the specified P-VOL is defined as the command device.

4B22

The pair cannot be resynchronized because the specified volume is in failover in PPRC.

4B23

The pair cannot be split because the specified volume is in failover in PPRC.

4B2F

The pair operation was rejected because the online microcode is being replaced.

4B32

The pair cannot be created because the specified P-VOL is one of the following:

  • Used by Compatible FlashCopy® V2
  • Used by Compatible Software for IBM® FlashCopy® SE
  • A TSE volume

4B85

The consistency group paircreate or pairresync was rejected because the specified P-VOL is a Compatible FlashCopy® V2 T-VOL.

4B86

The paircreate or pairresync (managed by cylinder) was rejected because the specified P-VOL is a Compatible FlashCopy® V2 T-VOL.

4BE0

The pair operation was received but could not be performed because the necessary shared memory is not mounted in the primary storage system.

4BEB

The pair operation by CCI cannot be performed because the specified volume is in a PPRC multi-target configuration.

9100

The command cannot be executed because user authentication is not performed.

B920

The pair cannot be created because the system identifier is not correct.

B927

You cannot run the following operations to a pair in a 2DC configuration:

  • Swap Suspend
  • Takeover

B928

The pair cannot be created because the mirror ID is invalid.

B929

The pair operation was rejected because the microcode is being replaced.

B92A

The pair cannot be created because the specified volume is a command device.

B934

The pair cannot be created because TrueCopy for Mainframe is not installed.

B935

S-VOL hide mode is not supported.

B93B

The specified volume is a P-VOL. The pair cannot be released because the P-VOL is specified as an S-VOL.

B941

The specified volume is an S-VOL. The pair cannot be released because the S-VOL is specified as a P-VOL.

B945

The command was rejected because the volume is unpaired.

B952

The specified LU is not defined. The DKC configuration might have been changed. Restart CCI.

B97B

The operation cannot run because pair status is either PSUS (by user) or PSUE (because of failure).

B97C

The command was rejected because the volume is unpaired.

B990

The pair cannot be created because the consistency group ID is greater than is allowed.

If this error occurred when you did not specify the consistency group ID, contact customer support.

B994

The Swap Resync operation cannot be performed because the S-VOL is not in PSUS or SSWS status. (Swap Resync resynchronizes differential data when the S-VOL is swapped for the P-VOL.)

B998

The pair cannot be created because the secondary system path setting is invalid.

B99B

The pair cannot be created because TrueCopy Asynchronous for Mainframe is not supported.

B9BD

The DKC LDEV configuration might have been changed while starting CCI. Restart CCI.

B9C0

The resource of the command device has run out.

C05E

The pair split request was rejected because secondary system and primary system were not paired with the specified serial numbers and SSIDs.

C06A

The pair cannot be deleted because the specified volume is in Simplex status.

C073

The pair deletion request was rejected because secondary system and primary system were not paired with the specified serial numbers and SSIDs.

C074

A request for a paircreate or pairresync operation was rejected because the TrueCopy for Mainframe program product is not installed.

C0A1

The pair cannot be split because the S-VOL was not paired with the P-VOL.

C0A2

A request for a pairsplit -S operation was rejected because the S-VOL was not paired with the P-VOL using the paircreate command.

C0F2

The pair cannot be created because the specified DKC is the same for the primary and secondary system.

C162

The pair cannot be resynchronized because the pair was not in the PSUS or PSUE status.

C16B

The pair cannot be created because the S-VOL is not available.

C184

A request for a pairsplit -S operation was rejected because the status change of the S-VOL failed.

C189

A request for a pairsplit -S operation was rejected because the pair status was invalid.

C18A

A request for a pairsplit -S operation was rejected because the status of the volume is being changed or the group contains a pair of which status is being changed.

C194

The pair cannot be split because the S-VOL pair status was in transition.

C195

A request for a pairsplit -r operation was rejected because the pair status was already PSUS or PSUE.

C198

The group includes no pair that can be split.

C199

A request for a pairsplit -r operation was rejected because the status of the volume is being changed or the group contains a pair of which status is being changed.

C1BE

The pair's status cannot be changed during the power-on processing of the DKC.

C1D6

The command was rejected because it was issued to a non-TCz pair volume.

C211

The command was rejected because the specified volume is a P-VOL. Forcibly delete the pair and run the command again.

C212

The command was rejected because the specified volume is an S-VOL. Forcibly delete the pair and run the command again.

C214

The command was rejected because the secondary system is not registered, or the registered secondary system information is invalid.

C215

The command was rejected because an internal logical error has occurred.

C218

The command was rejected because the pair status is invalid.

C21A

The command was rejected because the P-VOL status is other than PSUS or PSUE.

C21C

The command was rejected because the secondary system is not registered, or the registered secondary system information is invalid.

C22A

The command was rejected because the pair was deleted on a volume other than P-VOL.

C22C

The command was rejected because the volume is unpaired.

C22D

The command was rejected because the specified volume is the volume other than the P-VOL.

C22E

The command was rejected because the pairsplit command specifying -P option (write protection of P-VOL) was issued to a volume whose status is not Duplex.

C233

The command was rejected because the S-VOL status is unpaired.

C234/C235/C236/C237

The command was rejected because an internal logical error has occurred.

C238

The command was rejected because the specified volume is the volume other than the P-VOL.

C239

The command was rejected because the pair was resynchronized on a volume whose status is other than PSUS or PSUE.

C23A

The command was rejected because an internal logical error has occurred.

C23B

The command was rejected because the volume is unpaired.

C23C

The command was rejected because the volume status is other than PAIR or COPY.

C23D

The command was rejected because the command for TrueCopy Asynchronous for Mainframe was issued to a TrueCopy for Mainframe volume.

C23E

The command was rejected because the volume status is COPY.

C267

The pair cannot be created because the command was issued to a command device.

Alternatively, a pair for PPRC multi-target configuration cannot be created because the volume, in which 0x8000 is added to the LDEV ID of the volume used in the PPRC multi-target configuration, is set as a command device.

C271

The command was rejected because the specified consistency group ID is invalid.

C28B

The command was rejected because the horctakeover command was issued to a volume whose status is not SSWS.

C28C

The command was rejected because the secondary system is not registered, or the registered secondary system information is invalid.

C28D

There is no volume to which the horctakeover command can run.

C28E

The command was rejected because an internal logical error has occurred.

C297

The command was rejected because the specified volume is used as an S-VOL.

C2A0

The pair cannot be created because the capacity that is used by software products other than TrueCopy for Mainframe exceeds license capacity.

C2A1

The command was rejected because an internal logical error has occurred.

C2A3

The pair cannot be created because the used capacity exceeds the license capacity.

C2B3

The command was rejected because DP-VOL capacity is being changed.

C2B4

The command was rejected because an internal logical error has occurred.

C2B5

The pair cannot be created because the TCz P-VOL is being initialized by SIz.

C2B6

The command was rejected because releasing pages in DP-VOL is in progress.

C2C2

The pair cannot be created because the specified P-VOL is already in a PPRC multi-target configuration.

C2C6

The pair cannot be created because the specified P-VOL is already in a PPRC multi-target configuration.

C300

A copy pair associated with URz cannot be created because the Remote Replication Extended program product is not installed on the primary system.

C301

A copy pair associated with URz cannot be created because the Remote Replication Extended program product is not installed on the secondary system.

C304

The pair cannot be created because the S-VOL is a DP-VOL.

C305

The pair cannot be created because the capacity that is used by TCz in the secondary system exceeds license capacity. Check license capacity, including for related software products.

C30D

The volume in the secondary system or another volume that belongs to the same group is changing to SMPL, PSUS, or PSUE status. Retry the operation after approximately 5 minutes.

C310

The NVS is not ON in the primary system.

C311

The storage system level cache is not valid in the primary system.

C312

The P-VOL is not in unpaired status.

C313

The P-VOL is not in PSUS or PSUE.

C314

The P-VOL is not in unpaired status.

C315

The P-VOL includes PIN data.

C316

The P-VOL is in the process of drive copy for failure assistance.

C317

The P-VOL is in the process of drive copy for maintenance.

C318

The P-VOL is terminating the copy task.

C319

The P-VOL is in the process of correction copy.

C31A

The P-VOL is in the process of correction access.

C31B

A request for creating or resynchronizing TCz pairs was received, but the command was rejected because the physical volume with the specified P-VOL is blocked.

C31C

The P-VOL is blocked and cannot be accessed.

C31D

The P-VOL is being formatted.

C31E

The P-VOL is read only.

C320

The number of remote paths between primary and secondary systems is 0 (not specified).

C321

The number of remote paths between primary and secondary systems is smaller than the minimum required.

C322

The DKC type of the primary system does not support TCz.

C324

The secondary system's sequence number, SSID, or CU is invalid.

C325

The NVS is not ON in the secondary system.

C326

The storage system level cache is not valid in the secondary system.

C327

The pair cannot be created because the P-VOL is not available for remote copy.

C328

The track formats of the P-VOL and the S-VOL do not match.

C32A

The S-VOL is protected by Volume Retention Manager.

C32B

The P-VOL is protected by Volume Retention Manager.

C32C

The S-VOL is protected by Volume Retention Manager.

C32D

The S-VOL is protected by Volume Retention Manager.

C32E

A request for a paircreate operation was rejected because the specified secondary system is an unsupported product.

C32F

The number of P-VOL cylinders in the TCz volume is not equal to or smaller than the number of S-VOL cylinders.

C330

P-VOL and S-VOL capacities are not the same.

C332

S-VOL cache is disabled.

C335

The S-VOL is the TCz asynchronous P-VOL.

C336

The S-VOL includes PIN data.

C337

The S-VOL is in reserve status.

C338

Copy pair cannot be created because of the either of the following reasons:

  • The S-VOL is requesting intervention, protected, or cannot be used.
  • The S-VOL is configured as the S-VOL or reserved volume of SIz, reserved volume of Volume Migration, or the volume of URz pair.

C339

The S-VOL is not available.

C33A

A request for a paircreate operation was rejected because the secondary system is not supported by TCz.

C33B

The corresponding volume cannot be specified as an S-VOL because the volume is used as another pair's S-VOL.

C33C

A request for a paircreate operation was rejected because the specified S-VOL was not mounted.

C33E

The pair cannot be created because the S-VOL is not installed or is blocked (DEV NOT READY status).

C33F

The corresponding volume cannot be specified as an S-VOL because the volume is already specified as a TCz pair volume.

C35C

The P-VOL is not accessible.

C370

There are fewer paths than the required minimum number because a path failure occurred or an invalid path was specified.

C371

The process that is performed after the copying process of Volume Migration in the S-VOL is in progress. Try again in a few minutes.

C372

The process that is performed after the copying process of Volume Migration in the P-VOL is in progress. Try again in a few minutes.

C373

A request for a paircreate operation was rejected because the specified S-VOL is an SIz reserved volume.

C378

The paircreate operation is rejected because the number of active paths is less than the dedicated number of minimum paths.

C379

The minimum number of paths that need to be set is not met because a path failure occurred or an invalid path was specified.

C37A

An internal error occurred.

C37B

The S-VOL is not available.

C37C

The storage system level cache is not valid in the secondary system.

C37D

The NVS is not ON in the secondary system.

C37E

The S-VOL cache is disabled.

C380

The primary system cache is in transition to blockage on one side.

C381

The primary system cache is in the process of being restored.

C382

The primary system cache is either in transition to blockage on one side or in the process of being restored on one side.

C388

The pair cannot be created because the emulation type is not available for the specified volume.

C38B

The secondary system is already used by TCz.

C38D

The S-VOL is not available.

C38E

The S-VOL is a device which is not supported by TCz.

C390

The S-VOL status is not PSUS or PSUE.

C391

The S-VOL cannot be copied.

C392

The S-VOL is in reserve status or a pair of which copy type is not TCz is already created.

C393

The S-VOL includes PIN data.

C394

The S-VOL is in online status.

C395

The pair cannot be created or resynchronized due to one of the following reasons:
  • The specified S-VOL is blocked.
  • The physical volume used as the S-VOL is blocked.
  • The correction access is in progress.

C398

The pair cannot be created because the emulation type is not available for the specified volume.

C39B

An internal error occurred.

C39E

The pair cannot be created because the capacity of the P-VOL exceeded the maximum volume capacity allowed to create a TCz pair.

C39F

The pair cannot be created because the capacity of the S-VOL exceeded the maximum volume capacity allowed to create a TCz pair.

C3A0

The P-VOL is a device not supported by TCz.

C3A5

The TCz pair cannot be created nor resynchronized because the specified data volume is in online status.

C3A6

The SSID or CU number of the secondary system is invalid.

C3A8

The device type combination between the P-VOL and S-VOL is invalid.

C3AA

The secondary system's cache is blocked on one side.

C3AB

The secondary system's cache is blocked on one side.

C3AC

TCz is not supported for this controller emulation type of the secondary system.

C3AD

The secondary system capacity exceeds the license capacity.

C3AE

TCz is not installed on the secondary system.

C3AF

The DKC type of the secondary system is not supported by TCz.

C3B1

The number of paths is smaller than the required minimum number of paths.

C3B3

An internal error occurred.

C3B5

The configuration combination of P-VOL and S-VOL is invalid

C3B6

The TCz P-VOL is an SIz pair volume.

C3B7

The TCz S-VOL is an SIz pair volume.

C3B8

An internal error occurred.

C3B9

The pair cannot be created because the LUN is not defined for the S-VOL.

C3BA

A request for a paircreate operation was rejected because of one of the following reasons:

  • The secondary system's SSID or CU number is not supported.
  • Though the secondary system's SSID or CU number is supported, the microcode of the primary system device does not support them.

C3BD

The P-VOL is in online status.

C3BE

The following volumes cannot be specified as a TCz P-VOL:

  • The SIz S-VOL is not in PSUS status.
  • The SIz P-VOL is in the process of reverse copy.

C3BF

An SIz S-VOL, SIz reserved volume, or SIz P-VOL in the process of reverse copy cannot be specified as a TCz S-VOL.

C3C0

When the P-VOL is an SIz S-VOL, the SIz volumes must be a one-to-one combination.

C3C7

A request for a paircreate operation was rejected because the specified volume was already part of a TCz or URz pair (including journal volumes).

C3CA

The S-VOL is reserved, or a secondary system, S-VOL, or the path between primary system and secondary system is in the busy status.

C3CD

The TCz S-VOL is an SIz pair volume.

C3D2

The DKC type of the secondary system is not supported by TCz.

C3D3

The SSID or CU number is invalid for the specified secondary system.

C3D4

The pair cannot be created because the P-VOL is being used by Volume Migration.

C3D6

The specified S-VOL is unavailable because the connecting port cannot recognize it.

C3D7

The pair status of secondary system's S-VOL is invalid.

C3D8

The pair cannot be created because the volume specified for the S-VOL is a system volume.

C3D9

The pair operation cannot be performed if the TCz P-VOL or the TCz S-VOL meets any of the following conditions:

  • The volume is a DP-VOL, and paired using a reserved volume of SIz or Volume Migration.

  • The volume is a DP-VOL and its capacity is being expanded, or pages are being released.

  • The capacity of the P-VOL and the S-VOL is not the same

  • The volume is being initialized by SIz.

C3DB

S-VOL pair status is not PSUS or PSUE.

C410

Operation failed due to either of the following reasons:

  • The S-VOL of a pair you selected is in the extended long busy state.
  • A communication time out error has occurred between the local storage system and the remote storage system.

C4FC

The required amount of shared memory for the operation is not installed in the secondary system.

CB12

TC, TCz and UR, URz cannot be mixed in the consistency group.

CB19

The secondary system consistency group cannot be deleted because reversing the P-VOL and S-VOL using the horctakeover command failed.

CB1A

Deletion of the secondary system consistency group was abnormally terminated because reversing the P-VOL and S-VOL using the horctakeover command failed.

CB1D

No dummy volume can be created in the S-VOL.

CB1F

The secondary system does not support TCz.

CB20

In referring to the function bit, the system information reference function was abnormally terminated.

CB21

In a Pairresync operation, all difference setting was abnormally terminated.

CB23

An internal error occurred.

CB60

TCz is not installed in the secondary system.

CB66

The TCz pair cannot be created or resynchronized because the differential bitmap area is not available due to one of the following reasons:

  • Free area for shared memory in the secondary system is insufficient.
  • Free area for DPz pool specified as the S-VOL is insufficient.

CB67

An additional shared memory is not installed in the secondary system.

CB68

The pair cannot be created or resynchronized because the free area for shared memory in the primary system is insufficient and the differential bitmap area cannot be reserved.

CB69

The pair cannot be created because the number of pairs exceeds the maximum number that can be created in a single consistency group.

CB6E

The paircreate operation cannot run because the P-VOL is a volume in a storage system from another company.

CB6F

The command was rejected because Soft Fence is set for the specified S-VOL.

CB71

The paircreate operation cannot run because the P-VOL is a migration volume in a storage system from another company.

CB73

The paircreate operation cannot run because the S-VOL is a migration volume in a storage system from another company.

CB75

The device is not recognized correctly.

CB76

The paircreate operation cannot run because the paths are specified per storage system.

CB77

The used capacity of the Volume Retention Manager software product on the secondary system exceeds the license capacity.

CB78

The paircreate operation cannot run because the specified S-VOL is defined as the command device.

CB7E

A request for a paircreate operation was rejected because the specified S-VOL belongs to a different CLPR than the registered consistency group's CLPR.

CB9E

A request for a paircreate operation was rejected in the secondary system due to one of the following reasons:

  • The function for defining a consistency group that contains multiple pairs of storage systems is not supported.
  • The function for defining a consistency group for open systems is not supported.

CBD7

The storage system is in internal processing. Try the operation again.

CBD8

A pair cannot be created because the specified P-VOL is one of the following:

  • A journal volume used for URz
  • A URz secondary volume that is not suspended

CBD9

The pair cannot be created because the specified S-VOL is used for Compatible FlashCopy® V2 or Compatible Software for IBM® FlashCopy® SE, or is the TSE volume.

CBDA

The paircreate operation cannot run because the used capacity of Volume Retention Manager on the secondary system exceeds the license capacity.

CBDC

A request for creating a TCz pair was received in the TCz-URz combination status. However, the command was rejected because the mirror ID of URz was 0.

CBDD

In configuring a TCz-URz multi-target configuration, a request for a TCz paircreate operation was rejected because the URz pair was in the process of copying.

CBE2

The paircreate operation cannot run because the P-VOL is a DPz pool-VOL.

CBE3

The paircreate operation cannot run because the S-VOL is a DPz pool-VOL.

CBE7

65,280 pairs or more cannot be created in one storage system.

CBEB

The pair cannot be created because the specified P-VOL is being shredded by Volume Shredder.

CBEC

The pair cannot be created because the specified S-VOL is being shredded by Volume Shredder.

CBED

The request for a paircreate operation was rejected because the specified S-VOL was a URz S-VOL or journal volume.

CBEE

The request for a paircreate operation was rejected because the specified P-VOL is already paired for either of the following purposes:

  • P-VOL for the differential data resync in URz
  • P-VOL for the primary site in the 3DC multi-target configuration with three URz sites

CBFA

The pair creation failed because of one of the following reasons:

  • A CHA in the secondary system for connecting mainframe is not installed.
  • All CHAs in the secondary system for connecting mainframe is blocked.

CBF3

The pair was not created because the specified P-VOL is either of the following:

  • An external volume mapped for moving data online
  • An external volume of which data direct mapping attribute is enabled

CBFC

The pair cannot be created because the consistency group ID is not within the supported range.

FD0C

The pair cannot be created or resynchronized because the differential bitmap area cannot be reserved due to one of the following reasons:

  • Free area for shared memory in the primary system is insufficient.
  • Free area for DPz pool specified as the P-VOL is insufficient.

FD0E

Internal processing is being processed in the specified S-VOL. Try again after a while.

FD0F

The pair was not created because the data direct mapping attribute of the specified P-VOL is enabled, and the function of R-DKC for mapping the volumes of an external storage system larger than 4 TB is not supported.

FD1B

The pair operation cannot be performed because the specified volume is not configured to use the PPRC multi-target function.

FD1C

The specified TCz pair cannot be created because it builds a PPRC cascade configuration. Alternatively, the pair cannot be resynchronized between the intermediate site and the secondary site, because the pair status of the primary site and the intermediate site in the PPRC cascade configuration is Pending.

FD1D

The pair operation to TCz pair cannot be performed, because the MCU or RCU uses a volume with CU number 0x80 or later and mainframe system function editing No. 5 is enabled for the MCU or RCU by using VSP One Block Administrator.

FD1E

The pair operation to the second TCz pair in a PPRC multi-target configuration cannot be performed because the specified primary volume is one of the following:
  • Target linkage with Compatible FlashCopy® V2
  • Preserve Mirror FlashCopy® function is in use

FD1F

The pair operation in a PPRC multi-target configuration cannot be performed because Remote Replication Extended is not installed on the specified MCU.

FD20

The TCz pair cannot be created or resynchronized because the URz delta resync pair exists on the specified P-VOL.

FD24

When a TCz pair and a SIz pair share the same volume as the P-VOL or the S-VOL, the TCz pair operation cannot be performed because the differential data management differs between the TCz pair and the SIz pair.