ATTIME suspend function operating specifications

True Copy for Mainframe User Guide for VSP One Block 85

Version
10.5.x
FileSize
2745 KB
Audience
anonymous
Part Number
MK-26VSP1B036-02
ft:lastEdition
2026-06-23
Product
SVOS

The following table lists the operating specifications of the ATTIME suspend function for ShadowImage for Mainframe combined with TrueCopy for Mainframe.

Item Description
Registering and cancelling split time

Before you run split processing, you can overwrite the existing split time. After the split processing is executed, you cannot overwrite the split time. The registered split time is still valid after the split processing is performed on a ShadowImage for Mainframe pair. Register the next split time after you perform pair resynchronization from Business Continuity Manager for the consistency group of ShadowImage for Mainframe that has previously been split-processed.

When the storage system is powered off, the split time registered for the ShadowImage for Mainframe pair in the storage system is cancelled. If you turn off the power of the primary site of a TrueCopy for Mainframe pair, the split time registered in the ShadowImage for Mainframe pair combined with the TrueCopy for Mainframe pair at the secondary site will not be cancelled.

The registered split time is still valid after you switch between TrueCopy for Mainframe primary and secondary volumes using Business Continuity Manager, PPRC commands, GDPS, or CSM.

Consistency groups You can register split time in pairs when the pairs belong in the consistency groups of ShadowImage for Mainframe. You can register one split time in one consistency group of ShadowImage for Mainframe.
Split types You can select only one of the two split types of ShadowImage for Mainframe: Steady Split and Quick Split. For more information about split types, see the ShadowImage® for Mainframe User Guide.
Number of backup generations You can create up to three pairs of ShadowImage for Mainframe using the same ShadowImage for Mainframe primary volume. This allows you to create up to three generations of backup data.
Timing of split processing The split time and the actual start time of the split processing do not necessarily coincide. Depending on the number of ShadowImage for Mainframe pairs and the timing of receiving host I/O, the start time of the split processing will vary.
Timeout settings If there is a long distance between the primary and secondary storage systems, or if there is a delay in data transfer due to line equipment, you might not be able to detect host I/O with a timestamp exceeding the split time even after the specified timeout period has elapsed from the split time. In this case, the split processing for the ShadowImage for Mainframe pair is executed after the timeout period has elapsed. The timeout value is variable, so set the timeout value according to your environment. We recommend that you set the timeout value to a value greater than the host MIH time and the RIO MIH time. The recommended timeout value is 1 minute or more. Note that the default timeout value is less than 0 minutes.