Calculating the maximum number of pairs

True Copy for Mainframe User Guide for VSP One Block 85

Version
10.5.x
FileSize
2745 KB
Audience
anonymous
Part Number
MK-26VSP1B036-02
ft:lastEdition
2026-06-23
Product
SVOS

The maximum number of pairs you can have in a single storage system is based on the following:

  • Number of cylinders in the volumes, which must be calculated
  • Number of bitmap areas required for a TrueCopy for Mainframe volume

    This is calculated using the number of cylinders.

Note:

Bitmap areas are not used for DP-VOLs with volume capacity larger than 262,668 cylinders. Therefore, you do not need to calculate the maximum number of pairs when creating a TCz pair with a DP-VOL that is larger than 262,668 cylinders.

  1. Calculate the number of cylinders.
    1. Calculate the number of logical blocks in the storage system.
      number-of-logical-blocks = volume-capacity-in-bytes / 512
    2. Calculate the number of cylinders.
  2. Calculate the number of bitmap areas per volume.
    In the following calculation, differential data is measured in bits. 122,752 bits is the amount of differential data per bitmap area.

    number-of-bitmap-areas = ceil ( (number-of-cylinders × 15) / 122,752)

    Note:

    Performing this calculation for multiple volumes can result in inaccuracies. Perform the calculation for each volume separately, and then total the bitmap areas. The following examples show correct and incorrect calculations. Two volumes are used: one volume of 10,017 cylinders, and another volume of 32,760 cylinders

    Correct calculation

    ceil ((10,017 × 15) / 122,752) = 2

    ceil ((32,760 × 15) / 122,752) = 5

    Total: 7

    Incorrect calculation

    10,017 + 32,760 = 42,777 cylinders

    ceil ((42,777 × 15) / 122,752) = 6

    Total: 6

  3. Calculate the maximum number of pairs, which is based on the following:
    • Number of bitmap areas required for TrueCopy for Mainframe (calculated above)
    • Total number of bitmap areas: 65,536

      Bitmap areas are also used by Universal Replicator and global-active device. Therefore, when you use these software applications together, subtract the number of bitmap areas for each software application from the total number of bitmap areas before calculating the maximum number of pairs for TrueCopy for Mainframe.

      Also, when TrueCopy for Mainframe and Universal Replicator for Mainframe share the same volume, regardless of whether the shared volume is the P-VOL or the S-VOL, subtract the number of bitmap areas for each software application from the total number of bitmap areas before calculating the maximum number of pairs for TrueCopy for Mainframe. For details about calculating the number of bitmap areas for other software products, see the documentation for the software product.

    Use the following formula to calculate the maximum number of pairs:

    maximum-number-of-pairs = floor (total-number-of-bitmap-areas-in-the-storage-system / required-number-of-bitmap-areas)

    Maximum number of TC pairs:

    • VSP One B85: 65,280

    Subtract the number of command devices (including virtual command devices) from the maximum number of TC pairs.