Pairs in the same consistency group must be in the PAIR/Duplex status when you begin the split operation in order to maintain consistency. Otherwise, when the operation completes, the pair status will be inconsistent.

The following tables show the pair status before and after the split operation.

For CCI:

Pair status before the split operation

Pair status after the split operation

All = Duplex

Some = Duplex, some = Suspend

All = Suspend

TC and TCz pairs

All = PAIR

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

Some = PAIR, some = PSUS

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

All = PSUS

TC: PSUS

TCz: Duplex

TC: PSUS

TCz: Duplex/Suspend

TC: PSUS

TCz: Suspend

For Business Continuity Manager:

Pair status before the split operation

Pair status after the split operation

All = Duplex

Some = Duplex, some = Suspend

All = Suspend

TCz pairs

All = PAIR

TCz: Suspend

TCz: Suspend

TCz: Suspend

Some = PAIR, some = PSUS

TCz: Suspend

TCz: Suspend

TCz: Suspend

All = PSUS

TCz: Suspend

TCz: Suspend