When splitting a pair using the pairsplit command, you can specify settings for read/write access control for the P-VOL and S-VOL in consistency groups after the pairsplit operation.

These settings are specified using CCI. The CCI settings for TC are optional.

The following tables show the effects of the settings on read and write access.

Interface

Setting

TC P-VOL

TCz P-VOL

Read

Write

Read

Write

CCI (pairsplit command)*

Write access prohibited (-p option)

Y

N

Y

N

No option selected

Y

Y

Y

Y

* The effect on read/write shown in this table applies to the TC P-VOL. When CCI is used with a TCz P-VOL, the effect is the same as "No option selected".

Interface

Setting

TC S-VOL

TCz S-VOL

Read

Write

Read

Write

CCI (pairsplit command)*

Read access permitted (-r option)

Y

N

N

N

Read/Write access permitted (-rw option)

Y

Y

Y

Y

No option selected

Y

N

N

N