Requirements for a CTG for multiple primary and secondary systems

True Copy for Mainframe User Guide for VSP One Block 85

Version
10.5.x
FileSize
2745 KB
Audience
anonymous
Part Number
MK-26VSP1B036-02
ft:lastEdition
2026-06-23
Product
SVOS
  • All requirements for a consistency group between one primary and one secondary storage system apply to a consistency group between multiple primary and secondary storage systems.
  • Both the primary and secondary systems must be VSP One B85 or VSP 5000 series series.
  • A consistency group can consist of a maximum of four primary and four secondary (paired) storage systems.
  • The microcode for both primary and secondary systems must support consistency groups between multiple primary and secondary systems. If it does not, pair creation results in failure.
    • If a storage system at the primary site does not support the consistency group functionality for multiple primary and secondary storage systems, a pair for a consistency group of one primary and one secondary storage system is created.
    • If a storage system at the secondary site does not support the consistency group functionality for multiple primary and secondary storage systems, no pairs can be created.
  • You must install the CCI version that supports consistency groups containing multiple primary systems and secondary storage systems.
  • Pair operations can be performed only from CCI. Pair operations from Business Continuity Manager are not supported.
  • Cascade configurations with Universal Replicator for Mainframe pairs are not supported.
  • Compatible FlashCopy® configurations are not supported.
  • If a consistency group is used in a PPRC multi-target configuration, an MTIR pair cannot be created between the secondary sites.