You can issue CGROUP FREEZE/RUN commands manually or through automation (such as with GDPS). The following is an example sequence of actions you can implement.
- Suspend host updates to all specified TCz P-VOL.
- Block the specified primary-secondary system path to stop update copy operations to S-VOLs.
If the specified primary system does not have any P-VOLs, the FREEZE command is run without performing any operations (paths are not blocked, SCP is not indicated).
- Change all P-VOLs to Suspend status.
- Resume host updates to suspended P-VOLs.
- Run the add secondary system operation to re-establish the blocked remote paths. After paths are established, make sure to specify the desired SCP time for the primary system. The range for SCP time is 0 to 518,400 seconds (144 hours), and the default is 120 seconds.
- After the path is reestablished, run the resynchronize pair operation.