Use the CESTPATH command to establish remote paths from a primary system to a secondary system when using fibre cable. CESTPATH also allows you to enter a Controller ID for the secondary storage system.

Requirements

  • Fibre Channel ports must be configured as initiator ports or RCU target ports before the CESTPATH and CDELPATH commands are issued.
  • When system option mode (SOM) 114 is enabled, ports are configured automatically when the CESTPATH and CDELPATH TSO commands are run (RCU target/initiator to initiator/RCU target). If this SOM is disabled, ports must be configured.
  • With Fibre Channel, do not use the CESTPATH and CDELPATH commands at the same time as the LUN Manager SCSI path definition function.

CESTPATH command syntax

Use the following syntax for the CESTPATH command:

CESTPATH DEVN (X'dev#) PRIM (X'ssid' serial# X'lss') SEC (X'ssid' serial# X'lss') LINK (X'aabbccdd') [CGROUP (YES|NO)]

When WWNN (World Wide Node Name) is specified, use the following syntax:

CESTPATH DEVN (X'dev#) PRIM (X'ssid' WWNN X'lss') SEC (X'ssid' WWNN X'lss') LINK (X'aabbccdd') [CGROUP (YES|NO)]
Note:
  • For CDELPATH, the syntax for both PRIM and SEC is the same as CESTPATH.
  • A unit check is reported on earlier model storage systems that do not support the syntax above.

CESTPATH parameters

When fibre is used, CESTPATH parameters are the following.

Parameter

Description

aa

Bit 0 - 3: secondary system controller ID

x2 – xF: Number stands for secondary system controller ID.

  • VSP One Block 85: x'9'
  • VSP 5000 series: x'8'

Bit 4-7: Unused (x0 fixed)

bb

Primary system port number (0x00-0xff)

cc

Secondary system port number (0x00-0xff)

dd

Secondary system CU number (0x00-0xfe)

When WWNN is specified, CESTPATH parameters are the following.

Parameter

Description

aabb

Primary system SAID (x'00 and port number)

ccdd

Secondary system SAID (x'00 and port number)

WWN is the unique number for the controller and is indicated as follows.