System behavior

True Copy for Mainframe User Guide for VSP One Block 85

Version
10.5.x
FileSize
2745 KB
Audience
anonymous
Part Number
MK-26VSP1B036-02
ft:lastEdition
2026-06-23
Product
SVOS

Note the following behaviors for split pairs:

  • The primary system stops performing update operations to the S-VOL. It may or may not continue accepting write I/Os to the P-VOL depending on the P-VOL fence level setting and split option.
  • If an update fails, the primary system reports a unit check and notifies the host that Write fails. This ensures that both the host system and application program regard the write operation to the P-VOL as failed.
  • If the primary system accepts subsequent write I/Os for a split P-VOL, the system records the updated data in the P-VOL tracks as differential data. When a split pair is resynchronized, the primary system copies the out of sync P-VOL tracks to the S-VOL as differential data.
  • TCz does not allow access to an S-VOL while the pair is split (when mode20=ON, Read access is accepted).
  • When a pair is split, whether user requested or due to failure, the primary system generates sense information to notify the hosts. If the host system supports IBM® PPRC, this notification results in an IEA494I, IEA075I, or IEA491E system console message, which indicates the reason for suspension. If "enable" is set for the -pprc_opt option (for setting PPRC support by host) of the raidcom modify remote_replica_opt command, the host generates a system console message including SIMs instead of an IEA491E message.