Checking S-VOL consistency with the P-VOL

True Copy for Mainframe User Guide for VSP One Block 85

Version
10.5.x
File Size
2745 KB
Audience
anonymous
Part Number
MK-26VSP1B036-02
ft:lastEdition
2026-06-23

S-VOL consistency refers to whether the data in the S-VOL is identical to the data in the P-VOL. This depends on the fence level setting, which determines whether data is copied to the P-VOL if an error occurs during an update to the S-VOL.

The following table shows S-VOL consistency information based on pair status and the P-VOL fence level setting.

S-VOL status (CCI) S-VOL status (BCM) Split type Fence level (CCI) Consistency of S-VOL
SMPL SIMPLEX - data, status, never Not consistent. The S-VOL does not belong to a pair. Even if you have created a pair using this volume, if the pair status is still SMPL, you must regard its data as not consistent with the P-VOL.
COPY PENDING - data, status, never Not consistent. The S-VOL is not synchronized because not all tracks have been copied from the P-VOL yet. This S-VOL must be initialized (or copied from the P-VOL at a later time).
PAIR DUPLEX - data, status Consistent. The S-VOL is synchronized with its P-VOL.
never Needs to be analyzed. The S-VOL requires further analysis to determine its level of consistency.
PSUE SUSPER(50) Initial copy failed data, status, never Not consistent. The S-VOL is not synchronized because not all tracks have been copied from the P-VOL yet. The S-VOL must be initialized (or copied from the P-VOL at a later time).
PSUS SUSPOP(04) Secondary Volume by Operator data, status, never Suspect. The S-VOL is not synchronized with its P-VOL if any write I/Os were issued to the P-VOL after the pair was split. Delete the pair, and then run the raidcom add remote_copy_pair command without the -copy_mode none option to re-create the pair. If you are sure that the data on the P-VOL did not change, run the command with the -copy_mode none option to recreate the pair.
PSUE SUSPOP/SUSPER (all other types) All other types data Consistent. The S-VOL is synchronized with its P-VOL.
status, never Suspect. The S-VOL is not synchronized with its P-VOL if any write I/Os were issued to the P-VOL after the pair was suspended. Restore the consistency of the S-VOL and update it,if required. The time of suspension indicated on the Last Update Time field of the Detailed Information dialog box(MCU SVP time) will help to determine the last time the S-VOL was updated.

Legend:

Data: Data in the secondary volume

Status: Status of the secondary volume

For pairs whose P-VOL fence level is set to "never" in the raidcom get remote_copy_pair command, further analysis is required to determine the S-VOL consistency. This can be determined by using sense information transferred by host failover, or by comparing the contents of the S-VOL with other files that are confirmed to be consistent (for example, database log files). The S-VOLs should be recovered using the files that are confirmed to be consistent.

Note: Actual data recovery must be done using recovery point data in the database operation log.