Pair operability in a PPRC cascade configuration

True Copy for Mainframe User Guide for VSP One Block 85

Version
10.5.x
FileSize
2745 KB
Audience
anonymous
Part Number
MK-26VSP1B036-02
ft:lastEdition
2026-06-23
Product
SVOS

The following table shows pair operations between site A (intermediate site) and site C (secondary site) in a PPRC cascade configuration:

  • Yes: The operation can be performed.
  • No: The operation cannot be performed (command is rejected).
Pair operations between site A (intermediate site) and site C (secondary site) Site where the operation originates Pair status between site B (primary site) and site A (intermediate site) and allowed operations
Duplex Pending Suspend
Create pairs Site A No No No
Site C - - -
Resynchronize pairs Site A Yes* No Yes
Site C No No No
Split pairs Site A Yes Yes Yes
Site C Yes Yes Yes
Delete pairs Site A Yes Yes Yes
Site C Yes Yes Yes
Failover Site A No No No
Site C Yes Yes Yes
Failback Site A No No No
Site C No No No

* When the intermediate site (A) is updated, the pair status at the intermediate site (A) and secondary site (C) changes to Suspend.

The following table shows pair operations between site B (primary site) and site A (intermediate site) in a PPRC cascade configuration.

  • Yes: The operation can be performed.
  • No: The operation cannot be performed (command is rejected).
Pair operations between site B (primary site) and site A (intermediate site) Site where the operation originates Pair status between site A (intermediate site) and site C (secondary site) and allowed operations
Duplex Pending Suspend
Create pairs Site B No No No
Site A - - -
Resynchronize pairs Site B Yes* Yes* Yes
Site A No No No
Split pairs Site B Yes Yes Yes
Site A Yes Yes Yes
Delete pairs Site B Yes Yes Yes
Site A Yes Yes Yes
Failover Site B No No No
Site A Yes Yes Yes
Failback Site B No No No
Site A Yes Yes Yes

* The pair status between the intermediate site (A) and secondary site (C) changes to Suspend.