Configuring PPRC cascade

True Copy for Mainframe User Guide for VSP One Block 85

Version
10.5.x
File Size
2745 KB
Audience
anonymous
Part Number
MK-26VSP1B036-02
ft:lastEdition
2026-06-23



  1. Create a PPRC multi-target configuration.
  2. At site B, perform Failover to the TCz volume that is paired with site A.
  3. At site B, perform Failback to the TCz volume that is paired with site A.
    The pair status at site A and site C changes to Suspend.
  4. Wait until the TCz pair status between site A and site B changes to Duplex.
    In a PPRC cascade configuration, when the TCz pair status between site A and site B is Duplex and the TCz pair status between site A and site C is other than Suspend, the TCz P-VOL status in site A and site C changes to Suspend automatically when host I/O is started in site B.