SSB codes for ShadowImage for Mainframe

ShadowImage for Mainframe User Guide for VSP One Block 85

Version
10.5.x
Audience
anonymous
Part Number
MK-26VSP1B035-02
ft:lastEdition
2026-05-04

You can use the Command Control Interface (CCI) or Business Continuity Manager (BCM) operation logs to troubleshoot ShadowImage for Mainframe (SIz) operations. The following procedure describes CCI and BCM error codes and how to locate and interpret them.

  1. Open one of the following:
    • The CCI or BCM window
    • The CCI or BCM operation log file
  2. In the log that is displayed, locate the log entry or error code you are investigating. You can use the SSB1/SSB2 error code combination to determine the cause of the error. The error codes are shown to the right of the equal symbol (=) in the log. The SSB1 code is the last four alphanumeric characters to the left of the comma (,). The SSB2 code is the last four alphanumeric characters to the right of the comma (,).
    • CCI or BCM window sample log entry:

      It was rejected due to SKEY=0x05, ASC=0x20,SSB=0xB9E1,0xB901 on Serial#(64015)

      SSB1 code: B9E1

      SSB2 code: B901

    • CCI or BCM operation log file sample error code:

      11:06:03-37897-10413- SSB = 0xb9a0,2089

      SSB1 code: B9A0

      SSB2 code: 2089

  3. Locate the description of the SSB2 error code in the following table.

    For details about errors that are not listed in this table, contact customer support.

For details about the CCI error codes, see the Command Control Interface User and Reference Guide.

For details about the BCM error codes, see the Business Continuity Manager User Guide.

SSB2 error codes for ShadowImage for Mainframe: SSB1 = 2E31, B9A0, B9A1, B9A2, B9A5, B9A6, B9AE, and B9AF

Error code (SSB2)

Description

-

An error occurred during an SIz pair task.

200D

The pair task was rejected because the specified DP-VOL is not associated with a pool.

201B

The CTG pair-split was rejected because the URz pair is other than PAIR/PSUS/SSUS/PSUE. The URz S-VOL was the SIz P-VOL included in the CTG on which the pair-split is being performed.

2026

The Quick Restore operation was rejected because the cache mode of the specified P-VOL is different from the cache mode of the external S-VOL.

203B The Quick Restore operation was rejected because volumes with and without Extent Space Efficient (ESE) attribute are mixed in the specified P-VOL and S-VOL.

2043

The volume you specified as a P-VOL was a volume using two mirrors included in a 3-URz-DC multi-target or cascade configuration. The operation was rejected because the volume was used as a URz data volume.

2044

The volume you specified as an S-VOL was a volume using two mirrors included in a 3-URz-DC multi-target or cascade configuration. The operation was rejected because the volume was used as a URz data volume.

2047

The pair task was rejected because the current microcode version does not support the specified P-VOL capacity.

2048

The pair task was rejected because the current microcode version does not support the specified S-VOL capacity.

204F

The pair task was rejected because the volume specified as the S-VOL was used as a Volume Migration source volume and the migration processing could not be suspended. Complete the migration processing of Volume Migration, and then retry the task.

205B

The pair was not created because the specified MU number is in use.

2060

The volume you specified as an SIz P-VOL was a volume of a URz pair. The pair task was rejected because the status of the URz pair is not in the required status.

2061

The volume you specified as an SIz S-VOL was a volume of a URz pair. The pair task was rejected because the status of the URz pair is not in the required status.

2067

Volumes of the specified pair are shared by TCz and URz.

  • The Quick Restore operation was rejected.
  • The reverse resynchronization was rejected because the TCz or URz pair is not split (PSUS/SSUS/PSUE status).

Cause of the error could be either of the following:

  • The Quick Restore operation was rejected because the volumes of the specified pair are shared by TCz and URz.
  • The Reverse Copy operation was rejected because the volumes of the specified pair are shared by TCz and URz, and TCz or URz is not Suspend status.

2071

The pair task was rejected because the volume specified as the P-VOL was used as a Volume Migration source volume and the migration processing could not be suspended. Complete the migration processing of Volume Migration, and then retry the task.

2078

Because the specified P-VOL was also a URz P-VOL for delta resync, one of the following errors occurred:

  • The Reverse Copy operation was rejected because the URz pair status is not PSUS/SSUS/PSUE.
  • The Quick Restore operation was rejected.

2079

The pair task was rejected because the specified S-VOL was also a URz P-VOL for delta resync.

2086

The pair task was rejected because the initialization process is being performed.

2089

The Quick Restore operation was rejected because you are formatting the volume you specified as a P-VOL using Quick Format.

For more information about formatting volumes using Quick Format, see the Provisioning Guide for your storage system.

208A

The Quick Restore operation was rejected because you are formatting the volume you specified as an S-VOL using Quick Format.

For more information about formatting volumes using Quick Format, see the Provisioning Guide for your storage system.

2097

The Quick Restore operation was rejected for one of the following reasons:

  • The P-VOL is also an DP V-VOL, but the S-VOL is an external volume.
  • The P-VOL is an external volume, but the S-VOL also an DP V-VOL.

2098

The Quick Restore operation was rejected because all the following conditions were met when you performed the Quick Restore operation.

  • Either of the following conditions are met:
    • The SIz P-VOL is a DP-VOL, and the SIz S-VOL is a normal volume.
    • The SIz P-VOL is a normal volume, and the SIz S-VOL is a DP-VOL.
  • The P-VOL is shared with a TCz pair or URz pair, and the pool to which the P-VOL belongs manages the differential data of the TCz pair or URz pair.

209A

The Quick Restore operation was rejected because all the following conditions were met when you performed the Quick Restore operation.

  • Either of the following conditions are met:
    • The SIz P-VOL is a DP-VOL, and the SIz S-VOL is a normal volume.
    • The SIz P-VOL is a normal volume, and the SIz S-VOL is a DP-VOL.
  • The S-VOL is shared with a TCz pair or URz pair, and the pool to which the P-VOL belongs manages the differential data of the TCz pair or URz pair.

209E

The pair task was rejected because the volume you specified as the P-VOL is a FICON® Data Migration volume.

20A2

The create pair task was rejected because the P-VOL is a DP-VOL for which the capacity is increasing.

20A3

The pair was not created because the S-VOL is a DP-VOL for which capacity is increasing.

20A9

The pair task was rejected because TIA is using the specified CTG ID.

20AA

The pair task was rejected because the volume specified as the P-VOL is a DP-VOL for which zero pages are being reclaimed.

20AB

The pair task was rejected because the volume specified as the S-VOL is a DP-VOL for which zero pages are being reclaimed.

20B0

The pair task was rejected because the volume you specified as the P-VOL is a DP-VOL and its capacity is increasing.

20B1

The pair task was rejected because the volume you specified as the S-VOL is a DP-VOL and its capacity is increasing.

20B4

The pair task was rejected because the volume you specified as the P-VOL is a DP-VOL that is not associated with a pool.

20B5

The pair task was rejected because the volume you specified as the S-VOL is a DP-VOL that is not associated with a pool.

20BD

The pair task was rejected because the emulation type of the volume you specified as the P-VOL is 3390-V.

20BE

The pair task was rejected because the emulation type of the volume you specified as the S-VOL is 3390-V.

20C5

The command was rejected because you were in the process of turning off the storage system's power.

20C9

The emulation type of the P-VOL was 3390-A, and the pair task is rejected because of one of the following reasons:

  • Mainframe Fibre Channel Board is not mounted.
  • Mainframe Fibre Channel Board is all blocked.

20CA

The S-VOL's emulation type was 3390-A, and the pair task was rejected because of one of the following reasons:

  • Mainframe Fibre Channel Board is not mounted.
  • Mainframe Fibre Channel Board is all blocked.

20D0

The P-VOL rejected the paircreate CCI command because the DP pool is initializing in the DP-VOL.

20D1

The S-VOL rejected the paircreate CCI command because the DP pool is initializing in the DP-VOL.

20D6

The pair task was rejected because Compatible Software for IBM® FlashCopy® SE is using the P-VOL or the P-VOL is a TSE volume.

20D7

The pair task was rejected because the S-VOL is a TSE volume.

20DC

You cannot use the specified P-VOL for SIz, because it is being used in SI.

20E4

The command was rejected because the SIz CTG pair created by BCM or PPRC and the SIz CTG pair created by CCI cannot co-exist when the UR S-VOL and the SI P-VOL share a volume.

20E6

CCI cannot execute CTG pair-split on a reserved CTG.

20E9

The pair task was rejected because the volume you specified as the P-VOL is a S-VOL for an existing pair, and the volume you specified as the S-VOL is the P-VOL for another existing pair.

20F0

The pair task was rejected because Soft Fence is set for the specified primary volume.

20F1

The pair task was rejected because Soft Fence is set for the specified secondary volume.

22F6

The pair task was rejected because the volume specified as the P-VOL is a target volume of Compatible FlashCopy® V2.

22F7

The pair task was rejected because the volume specified as the S-VOL is a source or target volume of Compatible FlashCopy® V2.

22F9

The Quick Restore or Reverse Copy operation was rejected because the volume specified as the S-VOL is a source or target volume of Compatible FlashCopy® V2.

2301

The pair task was rejected because there is not a sufficient amount of installed shared memory or SIz is not installed.

2306

The pair task was rejected because the LBA size of the specified P-VOL is not the same as the size of the specified S-VOL.

2309

The pair was not created because the number of pairs exceeded the maximum number of pairs.

230A

The pair was not created because the volume you specified as the S-VOL is the P-VOL of the SIz pair that has an MU number of 0.

230B

The pair task was rejected because the pair is being suspended or deleted.

2310

One of the following occurred:

  • Pair creation was rejected because the specified CTG ID had already been used for an L1 pair.
  • Pair creation was rejected because the specified CTG ID had already been used for an L2 pair.
  • Quick Restore or Reverse Copy was rejected because the volume you specified as the P-VOL is the S-VOL of the pair which is in Suspend/SUSPER.
  • Quick Restore operation was rejected because the VLL setting of the P-VOL is different from that of the S-VOL.
  • The pair task was rejected because the specified P-VOL and S-VOLs were a Compatible FlashCopy® or Compatible FlashCopy® V2 pair.
  • The reverse resynchronization was rejected because the pair of the specified P-VOL and S-VOLs is suspended (PSUE/SUSPER status).
  • The reverse resynchronization was rejected because the specified P-VOL and the S-VOL is the L2 pair.
  • The CTG pair-split was rejected because some of the pairs in the CTG were being resynchronized, split, or were already suspended.
  • The pair task was rejected because the pair status of the P-VOL, the S-VOL, or both showed that the pair could not receive the issued command.

2312

The pair task was rejected because the volume specified as the S-VOL is online from the host.

2314

The pair was not created because the volume you specified as the S-VOL is the S-VOL of another SIz pair that has been split (PSUS or SSUS/SUSPOP status).

231F

The Quick Restore or Reverse Copy operation was rejected because the P-VOL of the specified pair is online from the host.

2322

The pair task was rejected because there is not a sufficient amount of installed shared memory or initialization is not completed.

2323

The Quick Restore operation was rejected because the combination of the pool ID and CU number associated with the specified P-VOL and S-VOL is a mixture of even and odd numbers.

2324

The pair task was rejected because the number of slots of the volume you specified as the P-VOL exceeded the upper limit.

2325

The pair task was rejected because the number of slots of the volume you specified as the S-VOL exceeded the upper limit.

2326

The pair was not created because the volume you specified as the P-VOL had already had three S-VOLs.

2327

The pair was not created because the node volume specified as the P-VOL had already had two S-VOLs.

2328

The pair task was rejected because the pair configuration exceeded the number of the layers of the cascade configuration.

2329

The pair task was rejected because the volume you specified as the S-VOL is the S-VOL of an existing pair.

232A

The pair was not created because pairs that would exceed the license capacity were going to be created.

232F

The pair task was rejected because the volume you specified as the P-VOL is allocated as the destination of the Volume Migration.

2331

The pair task was rejected because the capacity of the specified P-VOL is not the same as the capacity of the S-VOL.

2332

The pair was not created because the volume you specified as the P-VOL had already had three S-VOLs.

2333

The pair task was rejected because the volume you specified as the P-VOL is not the P-VOL of the existing pair.

2334

The pair task was rejected because of either of the following reasons:

  • The pair task was rejected because the volume specified as the P-VOL had an emulation type that CCI does not support.
  • The CTG pair-split operation was rejected because the volume specified as the P-VOL is an intermediate volume.

2335

The pair task was rejected because the volume specified as the S-VOL had an emulation type that CCI does not support.

2336

The pair task was rejected because the emulation types of the specified P-VOL and S-VOL were different.

2337

The pair task was rejected because the volume specified as the P-VOL had already been the S-VOL.

233A

The pairresync CCI command was rejected because the volume you specified as the P-VOL is not an SIz P-VOL.

233B

The pair task was rejected because the volume you specified as the S-VOL is a root volume.

233C

The pair task was rejected because the volume you specified as the S-VOL is a node volume, and the volume you specified as the P-VOL is not the P-VOL for the specified S-VOL.

233D

The pairsplit CCI command was rejected because the specified P-VOL and S-VOLs were a L2 pair, and the L1 pair is not split (PSUS or SSUS/SUSPOP status).

233E

The pair task was rejected because the volume you specified as the P-VOL is being used as another SIz P-VOL, and also that pair's S-VOL is used as a TCz P-VOL.

233F

The pair task was rejected because the volume you specified as the S-VOL is the TCz P-VOL, and the pair is not in PSUS/SSUS/PSUE status.

2342

The pair task was rejected because the volume you specified as the S-VOL is the destination of the Volume Migration.

2343

The pair was not created because the volume you specified as the S-VOL had already been an S-VOL.

2344

The pair task was rejected because the volume you specified as the S-VOL for SIz pair tasks is not an S-VOL.

2346

The volume you specified as an SIz S-VOL is a TCz P-VOL. The pair task was rejected because the TCz pair is not in the required status.

2347

The volume you specified as an SIz S-VOL was a TCz S-VOL. The pair task was rejected because the TCz pair is not in the required status.

234A

Creation of the cascaded pair was rejected because the volume specified as the S-VOL was an intermediate volume.

234B

The pair task was rejected because the volume you specified as the S-VOL is the volume of the Volume Migration.

2350

The pair task was rejected because the specified P-VOL and the S-VOL for SIz pair tasks is not a pair.

2351

The pair task was rejected because the volume you specified as the P-VOL and the volume you specified as the S-VOL are the same.

2352

The pair was not restored because the specified P-VOL and S-VOLs is online to the host.

2353

The pair was not deleted because the specified P-VOL and S-VOLs are in the process of being Quick Split.

2354

The pairresync CCI command was rejected because the P-VOL and S-VOLs is in the process of being Steady Split.

2357

The pair creation was rejected because the volume you specified as the S-VOL is the P-VOL of the pair you are splitting or the P-VOL of the pair you are reverse resynchronizing.

2358

The pairresync CCI command was rejected because the volume you specified as the S-VOL is the P-VOL of the splitting pair.

235B

The volume you specified as a P-VOL is a TCz P-VOL. The Reverse Copy or Quick Restore operation was rejected because the TCz pair is not in PSUS/SSUS/PSUE status.

235C

The volume you specified as the P-VOL is a TCz S-VOL. The Reverse Copy or Quick Restore operation was rejected because the TCz pair is not in PSUS/SSUS/PSUE status.

235D

The volume you specified as an S-VOL was a TCz P-VOL. The Reverse Copy or Quick Restore operation was rejected because the TCz pair is not in PSUS/SSUS/PSUE status.

236C

The reverse resynchronization was rejected because the volume you specified as the P-VOL has the S-VOL Disable attribute assigned by the Data Retention Utility.

236D

The pair task was rejected because the volume you specified as the S-VOL has the S-VOL Disable attribute assigned by the Data Retention Utility.

2370

The pair task was rejected because the volume you specified as the P-VOL is not mounted.

2371

The pair task was rejected because the volume you specified as the P-VOL is blocked.

2372

The pair task was rejected because the volume you specified as the P-VOL is being formatted or shredded.

2373

The pair task was rejected because the volume you specified as the P-VOL is a command device.

2374

An SIz pair cannot be created, because the differential data management specified at the pair creation differs from that for a different SIz pair that uses the specified P-VOL.

2380

The pair task was rejected because of one of the following reasons:

  • The volume you specified as the S-VOL is not mounted.
  • The MU number is 3 or greater.

2381

The pair task was rejected because the volume you specified as the S-VOL is blocked.

2382

The pair task was rejected because the volume you specified as the S-VOL is being formatted or shredded.

2383

The pair task was rejected because the volume you specified as the S-VOL is a command device.

2387

The pair was not created because the volume you specified as the P-VOL is the volume for Volume Migration.

2394

The pair was not registered in the CTG because the number of the pairs assigned to the CTG has exceeded the defined maximum number of pairs.

2395

The pair task was rejected because you are reverse resynchronizing the pair sharing the specified volume as the P-VOL.

2396

The pair task was rejected because you are reverse resynchronizing the L1 pair sharing the specified P-VOL as the root volume.

2397

The pair task was rejected because you are reverse resynchronizing the L2 pair sharing the specified P-VOL or S-VOL as the node volume.

2398

Quit Restore or Reverse Copy was rejected because the pair is not in PSUS(SSUS)/SUSPOP or PSUE/SUSPER status.

2399

Quit Restore or Reverse Copy was rejected because some of the pairs sharing the specified volume as the P-VOL are not in PSUS or SSUS/SUSPOP/PSUE/SUSPER status.

239D

The pair was not created because you have set the Protect attribute for the volume you specified as the P-VOL using BCM.

239E

The pair was not created because you set the Protect attribute for the volume you specified as the S-VOL using BCM.

23A9

The Quick Restore or Reverse Copy operation was rejected because the volume specified as the P-VOL had been specified as a Concurrent Copy (CC) primary volume.

23AB

The Quick Restore or Reverse Copy operation was rejected because the volume specified as the S-VOL had been specified as the Concurrent Copy (CC) primary volume.

23AF

Registration of a pair into the CTG from CCI was rejected because the specified CTG ID is reserved for BCM/PPRC.

23B7

An SIz pair cannot be created, because the differential data management specified at the SIz pair creation differs from that for a TCz pair that uses the specified P-VOL.

This problem might occur due to either of the following reasons:
  • If the SIz P-VOL and the TCz P-VOL share the same volume, the differential data management differs between the SIz pair and the TCz pair.
  • If the SIz P-VOL and the TCz S-VOL share the same volume, the differential data management differs between the SIz pair and the TCz pair.

23B8

An SIz pair cannot be created, because the differential data management specified at the SIz pair creation differs from that for a TCz pair that uses the specified S-VOL.

This problem might occur due to either of the following reasons:
  • If the SIz S-VOL and the TCz P-VOL share the same volume, the differential data management differs between the SIz pair and the TCz pair.
  • If the SIz S-VOL and the TCz S-VOL share the same volume, the differential data management differs between the SIz pair and the TCz pair.

23BB

The pair was not created because the volume you specified as the S-VOL could not be used as the S-VOL because of Volume Security settings.

23BE

An SIz pair cannot be created, because the differential data management specified at the SIz pair creation differs from that for a URz pair that uses the specified P-VOL.

This problem might occur due to either of the following reasons:
  • If the SIz P-VOL and the URz P-VOL share the same volume, the differential data management differs between the SIz pair and the URz pair.
  • If the SIz P-VOL and the URz S-VOL share the same volume, the differential data management differs between the SIz pair and the URz pair.

23BF

An SIz pair cannot be created, because the differential data management specified at the SIz pair creation differs from that for a URz pair that uses the specified S-VOL.

This problem might occur due to either of the following reasons:
  • If the SIz S-VOL and the URz P-VOL share the same volume, the differential data management differs between the SIz pair and the URz pair.
  • If the SIz S-VOL and the URz S-VOL share the same volume, the differential data management differs between the SIz pair and the URz pair.

23EF

The pair was not deleted because the P-VOL and S-VOL are in the process of being Quick Split.

23F1

The pair was not created because the CTG identifier you specified is not supported.

23F5

The pair task was rejected because you set a split time for the CTG.

9100

You cannot run the command because the system did not authenticate your user information.

B911

The pair task was rejected because the specified volume did not exist.

B912

The pair was not created because the specified S-VOL does not exist.

B913

The pair task was rejected because the mirror ID is invalid.