You can enable the FICON® encryption functions by using Fibre Channel Endpoint Security for Mainframe.
The storage system monitors the connection status of all key management servers (KMSs), however, a SIM code is output only when the number of available key management servers becomes one or fewer.
If you need to detect a connection failure even when only one key management server is affected, use an external monitoring system.
The following table summarizes the workflow for using Fibre Channel Endpoint Security for Mainframe.
The following administrators in the system department must perform the operations:
- Storage administrator
- Security administrator
- Mainframe host administrator
- Key management server (KMS) administrator
| Step | Category |
Task (Skip the step if the operation is already performed.) |
Reference | Person responsible for the operation |
|---|---|---|---|---|
| 1 | Restrictions | Verify the restrictions on Fibre Channel Endpoint Security for Mainframe. |
See Restrictions on using Fibre Channel Endpoint Security for Mainframe, Restrictions on MIH timer value that apply when using Fibre Channel Endpoint Security for Mainframe, and Restrictions on the OS IPL procedure that apply when using Fibre Channel Endpoint Security for Mainframe. |
Security administrator Mainframe host administrator KMS administrator |
| 2 | Configuring a host environment | Verify the host requirements and set up the host. | See Host requirements. | Mainframe host administrator |
| 3 | Configuring a storage system environment | Update the DKCMAIN microcode version. | See Storage system requirements. | Maintenance personnel* |
| 4 |
Install an additional channel board that supports FICON® encryption. Alternatively, replace the channel board with the FICON® encryption supported one. (Skip this step if you use a channel board with FICON® encryption pre-installed.) |
Maintenance personnel* | ||
| 5 | Install the required software license key that supports FICON® encryption. | Storage administrator or maintenance personnel | ||
| 6 | Configuring KMS environments | Connect KMSs to a LAN environment where the KMSs can communicate with the storage system. | See Key management server requirements. | KMS administrator |
| 7 | Configure the KMSs. | |||
| 8 |
Connecting between the storage system and KMSs (Storage system) |
Connect the storage system to a LAN environment where the storage system can communicate with KMSs. (Connect to a PUBLIC port on the AMC. Perform operations such as cable installation according to the connection environment.) |
N/A | Maintenance personnel* |
| 9 | Obtain a client certificate to be registered with the storage system and the KMSs. | See Obtaining a client certificate. | Security administrator | |
| 10 | Register the KMS information and the client certificate on the storage system, and then establish the connection to the KMSs. | See Establishing connections between the storage system and key management servers. | Security administrator | |
| 11 | Set up of host port authentication and encryption of data-in-flight (Storage system) | Stop the I/O operations to the target ports for which host port authentication and encryption of data-in-flight are to be performed, and then take the channel paths offline from the hosts. | See Configuring Fibre Channel Endpoint Security for Mainframe. |
Security administrator Mainframe host administrator |
| 12 | Configure Fibre Channel Endpoint Security for Mainframe. | |||
| 13 | Restore the channel paths to online. | |||
| 14 | Verify that the connection between host port authentication and encryption of data-in-flight is established. | |||
| 15 | Operation | Verify the port authentication and encryption of data-in-flight settings on the host. | See Verifying the port authentication and encryption of data-in-flight settings on the host. |
Security administrator Mainframe host administrator |