The following table shows use cases for maintenance.
| Item | Use case | CCI |
VSP One Block Administrator |
REST API |
|
|---|---|---|---|---|---|
|
Detailed API |
Simple API |
||||
| Verifying the status | Verify health status | No | Yes | No | No |
| Obtain list of alert information | No | Yes | Yes | No | |
| Alert monitoring settings | Add a destination address of an alert notification email | No | Yes | Yes | No |
| Delete a destination address of an alert notification email | No | Yes | Yes | No | |
| Obtain alert notification setting information | No | Yes | Yes | No | |
| Obtain SNMP settings information | No | Yes | Yes | No | |
| Audit Log Settings | Obtain forwarding destination information for audit logs | No | Yes | Yes | No |
| Others |
Block the selected LDEV (raidcom modify ldev) |
Yes | No | Yes | No |
|
Restore the selected blocked LDEV (raidcom modify ldev) |
Yes | No | Yes | No | |
|
View the system option mode or advanced system settings (raidcom get system_opt/raidcom get user_system_opt) |
Yes | No | No | No | |
|
Set the system option mode or advanced system settings (raidcom modify system_opt/raidcom modify user_system_opt) |
Yes | No | No | No | |
| Power on the storage system | No | Yes | Yes | No | |
| Power off the storage system | No | Yes | Yes | No | |
| Obtain the storage system power status | No | No | Yes | No | |
| Obtain the storage system date and time | No | Yes | Yes | No | |
| Obtain the list of available time zones for the storage system | No | No | Yes | No | |
|
Obtain storage system information (serial number, model, microcode version) (raidcom get system) |
Yes | Yes | Yes | Yes | |
| Verify the notification history | No | Yes | No | No | |
|
Set the Description of the storage system (raidcom modify system) |
Yes | No | No | No | |
| Edit a login message | No | Yes | No | No | |
|
Obtain the AP number used on the storage system (raidcom get apn) |
Yes | No | No | No | |
|
Allow mismatch of even (or odd) numbers between a CU number of an ESE-VOL and a pool ID (raidcom modify system_opt) |
Yes | No | No | No | |
| Make external volumes available on the mainframe system1 | Not available | Not available | Not available | Not available | |
| Obtain Soft Fence or SPID Fence status2 | Not available | Not available | Not available | Not available | |
| Force release of Soft Fence or SPID Fence status2 | Not available | Not available | Not available | Not available | |
|
Enable or disable Super PAV on the storage system (raidcom modify mainframe_system_function) |
Yes | Yes4 | No | No | |
|
Enable or disable TCMF multi-target on the storage system (raidcom modify mainframe_system_function) |
Yes | Yes4 | No | No | |
|
Enable or disable Reserve Transfer on the storage system (raidcom modify mainframe_system_function) |
Yes | Yes | No | No | |
|
Enable or disable PPRCSUM on the storage system system (raidcom modify mainframe_system_function) |
Yes3 | Yes | No | No | |
|
Notes:
|
|||||