SIM codes for Fibre Channel Endpoint Security for Mainframe

Provisioning Guide for Mainframe Systems for VSP One Block 85

Version
10.5.x
File Size
1619 KB
Audience
anonymous
Part Number
MK-26VSP1B034-03
ft:lastEdition
2026-06-23

This following table summarizes the SIM reference codes output to report the status of the key management server (KMS) in Fibre Channel Endpoint Security for Mainframe. If the event listed in the table occurs, a SIM code is output to alert the user, and then SNMP trap is reported.

SIM code Event Notifications Solutions
Sent to host? Completion from maintenance utility? Sent to maintenance personnel?
663000 (Moderate) KMS is not configured. Yes Required Yes Configure the KMS by referring to Establishing connections between the storage system and key management servers.
663100 (Moderate) The KMS configurations on the host and the storage system are inconsistent. Yes Required Yes

Make sure that the KMS settings match the host settings by referring to Establishing connections between the storage system and key management servers

If this problem occurs again even after taking corrective actions, restart the ESM. If this problem still occurs again even after restarting the ESM, contact customer support.

7C0Cxx (Serious)

where

xx: AMC#

Failures occur on all servers registered in the KMS configurations. Yes Not Required. If the use of the FICON® encryption function is terminated without restoring the connection between the storage system and the KMS after this SIM is issued, the SIM will not complete automatically. In that case, complete the SIM using the maintenance utility. Yes

Verify the KMS configurations, the client certificate files, and the validity periods by referring to Establishing connections between the storage system and key management servers.

After making the necessary changes, perform a connection test, and then verify that the registered KMSs are connected correctly.

If the KMS is restored to the normal state, the SIM is automatically complete.

If the following issues persist even after taking corrective actions, the problem might be related to the network environment between the storage system and the KMSs, or to the KMSs. In such cases, contact your network administrator or KMS administrator.

  • The connection test fails.
  • The SIM is not complete even when the connection is normally established.
  • The SIM code recurs.

If there is no problem with the network or the KMS, restart the ESM. If this problem still occurs again even after restarting the ESM, contact customer support.

7C0Dxx (Moderate)

where

xx: AMC#

The number of normally functioning servers registered in the KMS configurations is reduced to only one. Yes Not Required. If the use of the FICON® encryption function is terminated without restoring the connection between the storage system and the KMS after this SIM is issued, the SIM will not complete automatically. In that case, complete the SIM using the maintenance utility. Yes

7C0Exx (Service)

where

xx: AMC#

The number of normally functioning servers registered in the KMS configuration is restored to two or more. Yes Not Required Yes No action is required. The SIM is automatically complete after the automatic notification is sent.

7d25xx (Moderate)

where

xx: AMC#

The KMS connection monitoring service is stopped. Yes Not Required Yes Restart the ESM. If the SIM is not complete after a while following the restart, contact customer support.