- Check the port number of the port for which you set T10 PI mode.
- Make sure the transfer speed of the SCSI port on the CHB is 16 Gbps or 32 Gbps.
- Make sure that the CHB is not set as the NVM subsystem port.
- Clear the error information of CCI configuration setting commands that run asynchronously.
- Enable or disable the T10 PI mode for the port.
- Check the error information of CCI configuration setting commands that run asynchronously.
Verify that the ERR_CNT value is 0.
- Obtain the information of the port for which the setting is changed, and then verify that the T10 PI mode is set as you specified.