V-VOL protection function

Provisioning Guide for Open Systems for VSP One Block 85

Version
10.5.x
File Size
3643 KB
Audience
anonymous
Part Number
MK-26VSP1B033-03
ft:lastEdition
2026-06-23
The V-VOL protection function enables you to protect the V-VOLs in a pool from read and write requests when a pool is full or when pool volumes are blocked. If the V-VOL protection function is enabled, the access attribute to the V-VOL is changed to protect.

Protect V-VOLs when I/O fails to Blocked Pool VOL protects the V-VOL from read and write requests if the pool-VOL is blocked.

Protect V-VOLs when I/O fails to Full Pool protects the V-VOL from read and write requests if the pool is full.

Data Retention Utility enables you to suppress data from being read or written to a V-VOL when a Dynamic Provisioning pool is full. Contact customer support for the suppression instructions. When configured according to the suppression method, the Protect attribute is automatically assigned to the V-VOL when the pool is full. The Protect attribute is also assigned to a V-VOL that is used with other software.

The requirements for using the V-VOL protection function are:

  • Data Retention Utility (DRU) must be installed.
  • The pool type must be Dynamic Provisioning.

The behavior of the V-VOL protection function depends on the settings of system option modes (SOMs) 729 and 803, as specified in the following tables.

SOM 729 Protect V-VOLs when I/O fails to Full Pool Behavior
OFF Disabled DRU protect attribute is not set
OFF Enabled DRU protect attribute is set
ON Disabled DRU protect attribute is not set
ON Enabled DRU protect attribute is set
SOM 803

Protect V-VOLs when I/O fails to Blocked Pool VOL

Behavior

OFF Disabled DRU protect attribute is not set
OFF Enabled DRU protect attribute is set
ON Disabled DRU protect attribute is not set
ON Enabled DRU protect attribute is set

The V-VOL protection function setting has no connection to the access attribute status of V-VOL. For example, even if you disabled the V-VOL protection function to the pool while the protect attribute was being enabled on the V-VOL, the protect attribute would still be enabled on the V-VOL. To change the access attribute to the attribute that is not Protect, use the raidvchkset command.

If you remove Data Retention Utility, the V-VOL protection function settings remain set in the pool but are no longer active. In this case, if you reinstall Data Retention Utility, the protection function settings made before Data Retention Utility was removed are reactivated in the pool.

If you use the V-VOL protection function, you cannot simultaneously use the following host mode options. You cannot use the V-VOL protection function for V-VOLs associated with the host group for which one or both host mode options are enabled:

  • Host mode option 63 ((VAAI Support Option for vStorage APIs based on T10 standards)
  • Host mode option 73 (Support Option for Windows Server 2012)