Guidelines for managing LUs

Provisioning Guide for Open Systems for VSP One Block 85

Version
10.5.x
File Size
3643 KB
Audience
anonymous
Part Number
MK-26VSP1B033-03
ft:lastEdition
2026-06-23
  • Do not perform these tasks when host I/O is in progress and the LU is in the host-reserved (mounted) status:
    • Removing LU paths
    • Disabling LUN security on a port
    • Changing the data transfer speed for Fibre Channel ports
    • Changing AL-PAs or loop IDs
    • Changing settings of fabric switches
    • Changing the topology
    • Change the host modes
    • Removing host groups
    • Removing iSCSI targets
    • Setting command devices
  • When adding a LUN path or creating an alternative LUN path, port redundancy must be considered.
Note: If you want to remove a host reservation on an LU that is used in a global-active device pair, make sure to remove the host reservations on both the P-VOL and the S-VOL. If you remove only one host reservation, a Reserve Conflict might occur when the host is replaced.