Configuration of interleaved parity groups

Provisioning Guide for Open Systems for VSP One Block 85

Version
10.5.x
FileSize
3643 KB
Audience
anonymous
Part Number
MK-26VSP1B033-03
ft:lastEdition
2026-06-23
Product
SVOS

If RAID configurations are RAID 1 (2D+2D) or RAID 5 (7D+1P), the interleaved parity group can be created by concatenating multiple parity groups. This table lists the RAID configurations and the number of parity groups that can be concatenated.

RAID configuration 2 concatenating 4 concatenating
RAID 1 (2D+2D) Available Not available
RAID 5 (7D+1P) Available Available

When concatenating parity groups, data in LDEVs (CVs) is allocated between the interleaved parity groups. Therefore, loads are dispersed because of the parity group concatenation, and the LDEV performance is improved.

The capacity of the created LDEV is managed by each of the parity groups that is in the interleaved parity group. The maximum capacity of an LDEV is the same as the capacity of the interleaved parity group.

Note: Even if the parity groups are concatenated, they cannot be regarded as a large single parity group.

See this example:

  • Creating the interleaved parity group by concatenating parity groups PG1-1 and PG1-2.
  • Creating LDEVs in each parity group that are in the interleaved parity group.
    • LDEV 1 in PG1-1
    • LDEV 2 in PG1-2