iSCSI and NVMe/TCP interface specifications

Provisioning Guide for Open Systems for VSP One Block 85

Version
10.5.x
FileSize
3643 KB
Audience
anonymous
Part Number
MK-26VSP1B033-03
ft:lastEdition
2026-06-23
Product
SVOS
Protocol layer Item Specifications
All iSCSI, NVMe/TCP target functions Supported.
iSCSI, NVMe/TCP initiator functions Supported.

However, 100-Gpbs Ethernet channel boards do not support the initiator functions.

Path switching For iSCSI:
  • Windows: HDLM or Microsoft DSM/MPIO can be used.
  • Linux: HDLM or Device Mapper Multipath can be used.
  • VMware: HDLM or Native Multipath can be used.

For details, contact customer support.

For NVMe/TCP:

  • Linux: Native Multipath can be used.
  • VMware: High Performance Plug-in (HPP) can be used.

For details, contact customer support.

Number of connected hosts (connections and subsystems)

  • For the 25-Gbps Ethernet channel board:

    255

    Since the load on the iSCSI port increases as the number of connections increases, connect with 127 connections per port or fewer.

  • For the 100-Gbps Ethernet channel board:

    255 subsystems per port

    Since the load on the NVMe/TCP port increases as the number of connections increases, connect with 127 connections per port or fewer.

Physical layer, MAC layer Link See the storage system specifications in the Hardware Guide for VSP One Block 85.
Transfer speed See the storage system specifications in the Hardware Guide for VSP One Block 85.
Connector type See the storage system specifications in the Hardware Guide for VSP One Block 85.
Cable See the storage system specifications in the Hardware Guide for VSP One Block 85.
Network switch L2 switch, L3 switch
  • 10 Gbps (optical): Conforms to IEEE 802.3ae (10GBASE-SR).
  • 25 Gbps: Conforms to IEEE 802.3by (25GBASE SR SFP28).
  • 100 Gbps (optical): Conforms to IEEE802.3bm (100GBASE-SR4)
Cascading switches Up to 5 stages can be cascaded. If you increase the number of cascaded switches, the number of host I/O delays increases. Keep the number of cascaded switches to the minimum necessary.
MAC address Assigned to each port (fixed value).

Worldwide unique addresses are set at shipment. MAC addresses cannot be changed.

Maximum transmission unit (MTU) 1500/4500/9000 bytes (Ethernet frames)
Jumbo frame Supported.
Link aggregation Not supported.
VLAN Supported.

VLANs can be configured in the range of 1 to 4094 (port-based VLANs for switches are also available).

TCP/IP IPv4 Supported.
IPv6 Supported.
Subnet mask Supported.
Gateway Supported.
DHCP Not supported.
DNS Not supported.
Ping transmission Supported.
IPsec1 Not supported.
TCP port number
  • For iSCSI: 3260 (default)
  • For NVMe/TCP:
    • Discovery controller: 8009 (default)
    • I/O controller: 4420 (default)

The TCP port number can be changed in the range of 1 to 65535. Note the following:

  1. When you change the TCP port number, also change the settings of the host to be accessed.
  2. Verify whether the new number is filtered and disabled by a switch on the path.
  3. For NVMe/TCP IO controllers, the range that can be set is 49152 to 65535 (excluding the port number used by the discovery controller).
Fragmentation Not supported.
Window size Supported.
  • For iSCSI:

    10-Gbps iSCSI channel board: 64 KB, 128 KB, 256 KB (default), 512 KB, 1024 KB

    25-Gbps Ethernet channel board: 64 KB, 128 KB, 256 KB (default), 512 KB, 1024 KB, 2048 KB

  • For NVMe/TCP:

    64 KB, 128 KB, 256 KB, 512 KB, 1024 KB (default), 2048 KB

iSCSI iSCSI name Both the IQN2 and EUI3 formats are supported.

A worldwide unique IQN value is automatically set when an iSCSI target is set. However, iSCSI names can be changed.

Error recovery level Level 0.

Errors are corrected when a host retries. Levels 1 and 2 are not supported.

Header digest, data digest Supported.

Header digest and data digest protect headers and data in iSCSI communication from errors. iSCSI ports use these functions based on the host settings. However, if the functions are used, performance degrades (the rate of degradation changes depending on the host capabilities and the content of communication).

CHAP Supported.

CHAP is used to authenticate that login is performed by the registered hosts to access storage systems4.

Mutual CHAP Supported (not supported for connection with Linux hosts).

Mutual CHAP is used to authenticate that login is performed by hosts to access the registered storage systems. Mutual CHAP is also called two-way authentication.

Number of registered CHAP users Up to 256 users per iSCSI port
iSNS Supported.

By using iSNS (Internet Storage Name Service), you can discover targets without directly knowing their IP addresses.

NVMe/TCP Header digest, data digest Supported.

Protects communication headers and data information from errors.

NVMe/TCP ports use this function according to the host-side configuration, but performance is degraded when used (the degradation rate varies depending on the host's capabilities and communication content).

Notes:

  1. Security Architecture for Internet Protocol: A group of protocols for authenticating and encrypting IP packets.
  2. IQN: iSCSI Qualified Name. The IQN format uses Internet domain names. Each name consists of a type identifier (IQN), year and month when a domain was established, domain name, and any name (string) you want to use.

    Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.Tar

  3. EUI: 64-bit Extended Unique Identifier. The IEEE EUI-64 format consists of a type identifier (EUI) and a hexadecimal EUI-64 identifier in ASCII code.

    Example: eui.0123456789ABCDEF

  4. According to the iSCSI standard, CHAP authentication can be performed in a login session where an iSCSI initiator logs in to an iSCSI target, and a discovery session where connectable iSCSI initiators are searched for. Both types of sessions are supported.