Available data-transfer speeds for FC ports

Provisioning Guide for Open Systems for VSP One Block 85

Version
10.5.x
FileSize
3643 KB
Audience
anonymous
Part Number
MK-26VSP1B033-03
ft:lastEdition
2026-06-23
Product
SVOS

The available data-transfer speeds for the Fibre Channel ports depend on the port type and the connection type.

The following table shows the available data-transfer speeds for 16-Gbps Fibre Channel ports (16-Gbps SFPs on Fibre 32-Gbps Ready channel board).

Connection type Data transfer speeds for 16-Gbps ports/SFPs
4 Gbps 8 Gbps 16 Gbps 32 Gbps Auto

FC-AL

Available

Available

Not available

Not available

Available

If this combination is specified, the maximum transfer speed that is automatically specified is 8 Gbps.

P-to-P

Available

Available

Available

Not available

Available (default)

If this default value is set, Fabric is set to ON automatically.

Fabric

Available

Available

Available

Not available

Available

The following table shows the available data-transfer speeds for 32-Gbps ports (32-Gbps SFPs) on the Fibre 32-Gbps Ready channel board.

Connection type Data transfer speeds for 32-Gbps ports/SFPs
4 Gbps 8 Gbps 16 Gbps 32 Gbps Auto

FC-AL

Not available

Available

Not available

Not available

Available

If this combination is specified, the maximum transfer speed that is automatically specified is 8 Gbps.

P-to-P

Not available

Available

Available

Available

Available (default)

If this default value is set, Fabric is set to ON automatically.

Fabric

Available

Available

Available

Available

Available

The following table shows the combinations of available data transfer speeds and topologies for Fibre Channel Board 32Gb V2.

Connection type Data transfer speeds for Fibre Channel Board 32Gb V2
8 Gbps 16 Gbps 32 Gbps Auto
FC-AL

Not available

FC‑AL cannot be specified as the connection type for this channel board.

P-to-P Available Available Available

Available (default)

If this default value is set, Fabric is set to ON automatically.

Fabric Available Available Available Available

The following table shows the combinations of available data transfer speeds and topologies for Fibre Channel Board 64Gb V2.

Connection type Data transfer speeds for Fibre Channel Board 64Gb V2
16 Gbps 32 Gbps 64 Gbps Auto
FC-AL

Not available

FC‑AL cannot be specified as the connection type for this channel board.

P-to-P Available Available Available

Available (default)

If this default value is set, Fabric is set to ON automatically.

Fabric Available Available Available Available

Considerations when setting transfer speeds

  • You cannot set the transfer speed if at least one of these conditions is met:
    • The host I/O processing is being performed.
    • The LU is in the host-reserved (mounted) status.
  • I/O processing that the user is not aware of, such as a health check of an OS or multipath software, might be in progress. If the I/O processing is in progress, the operations might not be performed. If this is the case, stop the I/O processing before the operations.

The following points apply when setting the speed:

  • If the HBA or switch supports 4, 8, 16, 32, or 64 Gbps, use 4, 8, 16, 32, or 64 Gbps for the data transfer speed of the CHB (FC) port, respectively.
  • If auto negotiation is required, some links might not be up when the server is restarted. Check the channel lamp. If it is flashing, disconnect the cable, and then reconnect it to recover from the link-down state.
  • The specified port speed is limited due to the combination of the type of the Fibre Channel port and the connection type topology. To configure the data transfer speed settings, use the raidcom modify port command.
  • If the transfer speed of the CHB (FC) port is Auto, the data might not be transferred at the maximum speed depending on the connected device.
  • Some fabric switches require that you specify point-to-point topology. If you enable a fabric switch, check the documentation for the fabric switch to determine whether your switch requires point-to-point topology.
  • When connecting a 64 Gbps-compatible Fibre Channel port to 64 Gbps-compatible external Fibre Channel devices (such as HBAs or switches) with the port transfer speed fixed at 64 Gbps, it might take approximately 10 to 25 seconds for the link to come up.
  • When connecting a 64 Gbps-compatible Fibre Channel port to 64 Gbps-compatible external Fibre Channel devices (such as HBAs or switches) with the port transfer speed set to auto negotiation, the link-up might take 30 seconds or more. If it is necessary for the link-up to complete within 30 seconds, use the port with the transfer speed fixed.
  • The data transfer speed when the link is up is determined by the data transfer speed that is set for a Fibre Channel port. Whether the Forward Error Correction (FEC) mode is enabled or disabled is determined by the data transfer speed when the link is up. If the FEC mode of the Fibre Channel port differs from the FEC mode of the fabric switch or the host bus adapter port, the connection might not be established.

    Data transfer speed/Port speed setting

    Data transfer speed when Fibre Channel port link is up

    FEC mode of Fibre Channel port

    16 Gbps or less

    16 Gbps or less

    Disabled

    32 Gbps or more

    32 Gbps or more

    Enabled

    Auto

    16 Gbps or less

    Example: When connecting a 16-Gbps fabric switch or host bus adapter port to a 32-Gbps or 16-Gbps Fibre Channel port.

    Disabled

    32 Gbps or more

    Example: When connecting a 32-Gbps fabric switch or host bus adapter port to a 32-Gbps Fibre Channel port.

    Enabled