Cache management device requirements

Provisioning Guide for Open Systems for VSP One Block 85

Version
10.5.x
FileSize
3643 KB
Audience
anonymous
Part Number
MK-26VSP1B033-03
ft:lastEdition
2026-06-23
Product
SVOS

Cache management devices manage the cache associated with volumes (LDEVs). Each LDEV requires at least one cache management device.

The storage system can manage up to 65,280 cache management devices.

The following table shows the support status of each management tool for the cache management device function.

Management tool Support status Supported DKCMAIN microcode version
VSP One Block Administrator No NA
VSP block storage REST API No NA
CCI Yes All versions

This table shows the maximum capacity of the cache management device.

Maximum capacity of cache management device
MB

(TB)

Blocks
3,145,548 MB

(2.99 TB)

6,442,082,304 blocks

Use this formula to calculate the number of cache management devices that a V-VOL requires. In this formula, the user-specified capacity is the user area capacity of a V-VOL.

  • V-VOL

    ceiling(user-specified-capacity / max-capacity-of-cache-management-device)

  • DRS-VOL

    ceiling(user-specified-capacity / max-capacity-of-cache-management-device) + ceiling(user-specified-capacity / max-capacity-of-cache-management-device x 2) x 2

where

ceiling: The value enclosed in ceiling( ) must be rounded up to the nearest whole number.

You can view the number of cache management devices by using CCI. For more information about the number and the maximum number of cache management devices in use, see the raidcom get system command. This operation is not available by using VSP One Block Administrator or VSP block storage REST API.