Recovering if a storage system failure occurs during the volume copy processing with Preserve Mirror FlashCopy

Compatible FlashCopy User Guide for VSP One Block 85

Version
10.5.x
Audience
anonymous
Part Number
MK-26VSP1B031-02
ft:lastEdition
2026-05-04

If a storage system failure occurs while an IBM OS utility or application such as DEFRAG is running the volume copy operation by using Preserve Mirror FlashCopy®, the data consistency between the P-VOL and the S-VOL of a TCz pair might not be guaranteed even if the operation is complete normally and the TCz pair is in the Duplex status.

If a SIM related to the storage system failure is reported during the volume copy processing using the utility or the application, verify if the data matches between the P-VOL and the S-VOL of the TCz pair by taking the following actions. If the data do not match, delete the TCz pair, and then retry the TCz pair creation.

  1. Run the PPRC CQUERY command in TCz.
    For details, see the restrictions on using Preserve Mirror FlashCopy® in the TrueCopy® for Mainframe User Guide.
  2. Alternatively, you can also use the raidcom get remote_copy_pair CCI command.
    WITHDRAWN is displayed for PRESERVE_MIRROR_STATUS.
    If you used Business Continuity Manager see the manual related to Business Continuity Manager