ICKDSF command terminates abnormally

Compatible FlashCopy User Guide for VSP One Block 85

Version
10.5.x
Audience
anonymous
Part Number
MK-26VSP1B031-02
ft:lastEdition
2026-05-04
When you execute the ICKDSF command to a TCz P-VOL or SIz to a P-VOL in Pending status, the ICKDSF job ends abnormally and generates a CC=12 error.

The following table explains how to avoid abnormal termination of ICKDSF commands:

Table. Avoiding abnormal termination of ICKDSF commands

Command

How to avoid abnormal termination

FLASHCPY ESTABLISH

  • Use the TSO command or the DFSMSdss command.
  • Check if a TCz pair or SIz pair is in Duplex or Suspend status, and then execute the FLASHCPY ESTABLISH command. To check the pair status, use the TSO CQUERY command.

FLASHCPY WITHDRAW

  • Use the TSO command.
  • Check if a TCz pair or SIz pair is in Duplex or Suspend status, and then execute the FLASHCPY WITHDRAW command. To check the pair status, use the TSO CQUERY command.

FLASHCPY QUERY

  • Execute the FLASHCPY QUERY or the FLASHCPY QUERY RELATIONS command to the T-VOL of the Compatible FlashCopy® relationship.
  • When you are going to execute the FLASHCPY QUERY or the FLASHCPY QUERY RELATIONS command on the S-VOL of a Compatible FlashCopy® relationship, check if a TCz pair or SIz pair is in Duplex or Suspend status, and then execute the command. Use the CQUERY command of the TSO to check the pair status