Using ICKDSF to establish FlashCopy SE relationships

Compatible FlashCopy User Guide for VSP One Block 85

Version
10.5.x
Audience
anonymous
Part Number
MK-26VSP1B031-02
ft:lastEdition
2026-05-04

Use the following steps to create a FlashCopy® SE relationship using ICKDSF FLASHCPY ESTABLISH:

  1. Set the T-VOL offline. If the ONLINTGT parameter is set to YES, the T-VOL will automatically be offline when creating relationships.
  2. Specify a JCL DD statement to use with the DDNAME parameter, or specify the S-VOL device number in the UNITADDRESS parameter.
  3. Specify the CU number, the LDEV number, and the device number of the T-VOL for the TARGETVOL parameter.
  4. Execute FLASHCPY ESTABLISH.
    FLASHCPY ESTABLISH UNIT(X'7000') TARGETVOL(X'00',X'01' ,7001) ONLINTGT(YES) SETGTOK(YES) MODE(NOCOPY)