The following tables show the parameters for the ICKDSF FLASHCPY QUERY and FLASHCPY QUERY RELATIONS commands.
|
Command |
Parameter |
Value |
Description |
|---|---|---|---|
|
FLASHCPY QUERY |
DDNAME or DNAME |
JCL statement |
Sets the JCL statement identifying the volume. If the host server OS is z/OS®, this parameter or the UNITADDRESS parameter is required. |
|
SYSNAME |
SYSNAME |
Sets the SYSNAME in the ASSGN system control statement. If the host server OS is VSE, this parameter is required. |
|
|
UNITADDRESS, UNITADDR, or UNIT |
Source device number |
Specifies the device number (device address) of the S-VOL on which you want to perform the FLASHCPY QUERY command. If the host server OS is z/OS®, this parameter or the DDNAME parameter is required. |
|
|
SOURCEVOL or SRCVOL |
CU number LDEV number SSID Serial number |
Specifies the CU number, the LDEV number, SSID, or the serial number of the S-VOL when you use the Remote FlashCopy® function. |
|
Command |
Parameter |
Value |
Description |
|---|---|---|---|
|
FLASHCPY QUERY RELATIONS |
DDNAME or DNAME |
JCL statement |
Sets the JCL statement identifying the volume. If the host server OS is z/OS®, this parameter or the UNITADDRESS parameter is required. |
|
SYSNAME |
SYSNAME |
Sets the SYSNAME in the ASSGN system control statement. If the host server OS is VSE, this parameter is required. |
|
|
UNITADDRESS, UNITADDR, or UNIT |
Source device number |