Using a Compatible FlashCopy T-VOL as a URz P-VOL

Compatible FlashCopy User Guide for VSP One Block 85

Version
10.5.x
Audience
anonymous
Part Number
MK-26VSP1B031-02
ft:lastEdition
2026-05-04

You can use a Compatible FlashCopy® T-VOL as a URz P-VOL regardless of the status of the URz pair. Note the following:

  • If a Compatible FlashCopy® volume and a URz volume cannot be shared, the host might receive a report that a Compatible FlashCopy® T-VOL is a PPRC P-VOL.
  • If the S-VOL and T-VOL of a Compatible FlashCopy® relationship are Dynamic Provisioning for Mainframe volumes, the number of pages remaining in the T-VOL might differ, depending on the timing.
  • If a Compatible FlashCopy® relationship is suspended during a copy operation, the shared URz pair is also suspended. Since data is copied asynchronously in URz, there will be a noticeable delay between the time the Compatible FlashCopy® is suspended and when the URz pair is suspended.
  • A URz P-VOL combined with the multiple primary system and the secondary system using CCI, and the Compatible FlashCopy® T-VOL cannot be shared.
  • The URz P-VOL in 3DC multi-target configuration using 3 URz sites and a Compatible FlashCopy® target volume cannot be shared.
  • The volume copy operation (of which a T-VOL is a URz P-VOL) might not be performed by using some applications on the host. For details, see Why you use IBM Db2® Cloning Tool for z/OS®.