Check ESM status

System Administrator Guide for VSP One Block 85

Version
A0-05-4x
Audience
anonymous
Part Number
MK-26VSP1B030-03
ft:lastEdition
2026-06-22
Product
Virtual Storage Platform One Block

Use the following procedure to check the status of the ESMs.

Note: If the ESMs on the AMCs are in any of the following statuses, wait for five minutes, reload the ESMs, and then check the status again:
  • Active on both AMCs
  • Standby on both AMCs
  • Starting on one or both AMCs
  • Error on one or both AMCs

If the status remains unchanged after reloading several times, contact customer support.

  1. Log in to the maintenance utility.
  2. In the toolbar on the left, select the AMC that is currently connected.
  3. Select Hardware - All Chassis in the upper left.
  4. Check the status (active or standby) of the currently connected AMC from System Information Settings - ESM Cluster Role in the upper right.