IP address and port information for accessing the storage system

System Administrator Guide for VSP One Block 85

Version
A0-05-4x
Audience
anonymous
Part Number
MK-26VSP1B030-03
ft:lastEdition
2026-06-22
Product
Virtual Storage Platform One Block

The Embedded Storage Manager modules (ESMs), which are software modules on the storage system controllers (AMCs), host the embedded management tools for VSP One Block. The ESMs on AMC-0 and AMC-1 are cluster-defined in an active-standby configuration.

The storage system provides two types of IP addresses for accessing the AMCs:

  • Service IP address

    The service IP address is the IP address assigned to the AMC that is active in the cluster. If the active AMC fails, the service IP address is taken over by the standby AMC. When you want to connect to the active AMC (AMC-0 or AMC-1), use the service IP address.

  • Static IP addresses

    The static IP addresses are the IP addresses assigned to the ESM on AMC-0 and the ESM on AMC-1. When you want to connect to a specific ESM on the storage system, use the static IP address.

Specify a static IP address and a service IP address for the firewall between the storage system and various external servers.

The following table lists the embedded management tools for the VSP One Block storage systems and specifies the protocol and port information for each tool.

Management tool Protocol TCP/UDP Source port number (management PC) Destination port number (storage system)
Maintenance utility

VSP One Block Administrator

VSP block storage REST API

HTTP TCP any 80
HTTPS TCP any 443
Embedded CCI SSH TCP any 20522