Configuring monitoring and auto correct settings

Disaster Recovery Solution User and Reference Guide

Version
10.0.x
Audience
anonymous
Part Number
MK-26HDRS004-00
ft:lastEdition
2026-02-24

The Monitor service periodically scans the arrays and Disaster Recovery Solution systems, collects information, and corrects conditions if appropriate and necessary. You can set the interval time for running this service and set options that identify and correct issues that are discovered during the scan.

  1. Go to Configuration.
  2. Click the Monitor tab, and click Edit to update the following settings:
    Monitor Scan Intervals
    Set the interval time in minutes between scans of the Monitor service to check the health status of the system and its components and to auto correct discovered issues.
    Valid values are in the range between 10-60 minutes. The default value is 30.
    Automount File System
    Set this toggle switch to True to remount a file system automatically if it is unmounted
    The default is True.
    Autocorrect Issue Codes
    When you set the Autocorrect Error toggle switch for an issue to Yes, Disaster Recovery Solution attempts to auto correct that issue when detected.
  3. Click Save.