Action to be taken when PIN status occurs (event log KARS06501-C is output)

Virtual Storage Platform One SDS Block and SDS Cloud Troubleshooting Reference

Version
1.19.x
Audience
anonymous
Part Number
MK-24VSP1SDS029-03
ft:lastEdition
2026-04-07

When event log KARS06501-C (indicating that PIN status occurred) is output, troubleshoot the failure according to the following procedure.

  1. Obtain information about the storage controller by specifying the ID of the storage controller indicated in event log KARS06501-C.

    REST API: GET /v1/objects/storage-controllers/<id>

    CLI: storage_controller_show

    For details, see the VSP One SDS Block and SDS Cloud REST API Reference or VSP One SDS Block and SDS Cloud CLI Reference.

  2. Confirm the pinInformation value from the obtained storage controller information.

    If the pinInformation value is null, the failure indicated in this event log has been resolved and you do not need to take action. If the pinInformation value is other than null, collect the dump log files of VSP One SDS Block for all the storage nodes, and then contact customer support.