If a failure occurs during setup of each storage node, take action according to the following table.
For details about specific procedures for Hitachi Advanced Server HA800 series, HA800 G2 series, HA800 G3 series, and HA800 G6 series, see the iLO User Guide.
For details about specific procedures for physical servers other than Hitachi Advanced Server HA800 series, HA800 G2 series, HA800 G3 series, and HA800 G6 series, see the BMC documentation provided by the respective server vendors.
|
Symptom |
Action |
|---|---|
|
The screen layout of the console interface collapsed. |
Display another screen of the console interface, and then redisplay the screen whose layout collapsed. |
|
Keyboard entry operations are not reflected in the console interface screen. |
If the following case applies, take action as described:
If the preceding case does not apply, the BMC remote console might be unable to respond currently. Click the close ([x]) button at the top right of the BMC remote console window to close the window, redisplay the window, and then perform keyboard entry operations. |
|
When the setup user login screen of the console interface was displayed at the first-time login, [Login:] was displayed, instead of [Login:setup], on the first line. |
If the following case applies, take action as described:
If the preceding case does not apply, installation of storage software might have not been completed normally. Reperform installation of storage software. For details about the procedure, see Installing the storage software in the VSP One SDS Block Bare Metal Setup and Configuration. |
|
At the first-time login, the user entered the default password (hsds-setup) in the setup user login screen of the console interface but authentication did not succeed. |
If the following case applies, take action as described:
If the preceding case does not apply, installation of storage software might have not been completed normally. Reperform installation of storage software. For details about the procedure, see Installing the storage software in the VSP One SDS Block Bare Metal Setup and Configuration. |
|
The setup user password could not be set in the setup user login screen of the console interface. |
The setup user password that you wanted to set might not meet the requirements for the setup user password. Verify the requirements for the setup user password in step 3 of the procedure described in Setting up each storage node in the VSP One SDS Block Bare Metal Setup and Configuration. Then, reperform step 3 and subsequent steps in that procedure. |
|
When the setup user password was entered in the setup user login screen of the console interface, the following message appeared: "The account is locked due to 3 failed logins." |
The setup user's account was locked because an authentication attempt was unsuccessful three times in succession. The account is locked for one minute. After one minute has elapsed, reperform step 3 and subsequent steps in the procedure described in Setting up each storage node in the VSP One SDS Block Bare Metal Setup and Configuration. |
|
After the setup user password has been set, authentication did not succeed in the setup user login screen of the console interface. |
If the following case applies, take action as described:
If the preceding case does not apply, a password that differs from the one that you intended to use might have been set. Reperform installation of storage software and setup of each storage node. For details, see Installing the storage software and Setting up each storage node in the VSP One SDS Block Bare Metal Setup and Configuration. |
|
An error message with an ID that begins with KARS was displayed in the console interface screen. |
Take action according to the error message. Contact customer support if you are prompted to do so by the error message. |
|
The power of the physical server was turned off due to a power failure. |
Resolve the power failure, and then turn on the power of the physical server. After that, reperform the procedure described in Setting up each storage node in the VSP One SDS Block Bare Metal Setup and Configuration. |
|
Symptoms other than the above occurred and you could not set up each storage node. |
Start from the storage software installation again. For details, see Installing the storage software in the VSP One SDS Block Bare Metal Setup and Configuration. If the problem persists, take the screenshot of the window when the problem is occurring and contact the customer support. |