Operation |
Failure |
Reference |
|---|---|---|
|
Configuring a storage cluster |
One of the following conditions occurred during the procedure described in Installing the storage software in the VSP One SDS Block Bare Metal Setup and Configuration was being performed:
|
Action to be taken for a failure that occurred during installation of the storage software (Bare metal) |
|
One of the following conditions occurred during the procedure described in Setting up each storage node in the VSP One SDS Block Bare Metal Setup and Configuration was being performed:
|
Action to be taken for a failure that occurred during setup of each storage node (Bare metal) |
|
|
One of the following conditions occurred during the procedure described in Configuring a storage cluster in the VSP One SDS Block Bare Metal Setup and Configuration was being performed:
|
Action to be taken for a failure that occurred when configuring a storage cluster (Bare metal) |
|
|
Drives were not recognized after storage cluster configuration in the setup procedure. |
Action to be taken when drives cannot be recognized (Bare metal) |
|
|
Starting and stopping the storage cluster |
A failure occurred when starting and stopping the storage cluster. |
Action to be taken for a failure that occurred when starting and stopping the storage cluster |
|
A failure occurred when stopping the storage cluster. |
||
|
Adding storage nodes |
One of the following conditions occurred during the procedure described in Installing the storage software in the VSP One SDS Block Bare Metal Setup and Configuration was being performed:
|
Action to be taken for a failure that occurred during installation of the storage software (Bare metal) |
|
One of the following conditions occurred during the procedure described in Setting up each storage node in the VSP One SDS Block Bare Metal Setup and Configuration was being performed:
|
Action to be taken for a failure that occurred during setup of each storage node (Bare metal) |
|
|
The following occurred during storage node addition.
|
Action to be taken for a failure that occurred when adding storage nodes (Bare metal) |
|
|
Drives were not recognized after storage node addition. |
Action to be taken when drives cannot be recognized (Bare metal) |
|
|
Removing storage nodes |
The following occurred when the storage node was removed.
|
Action to be taken for a failure that occurred when removing storage nodes (Bare metal) |
|
Replacing storage nodes |
One of the following conditions occurred during the procedure described in Installing the storage software in the VSP One SDS Block Bare Metal Setup and Configuration was being performed:
|
Action to be taken for a failure that occurred during installation of the storage software (Bare metal) |
|
One of the following conditions occurred during the procedure described in Setting up each storage node in the VSP One SDS Block Bare Metal Setup and Configuration was being performed:
|
Action to be taken for a failure that occurred during setup of each storage node (Bare metal) |
|
|
The following occurred during storage node replacement.
|
Action to be taken for a failure that occurred when replacing storage nodes (Bare metal) |
|
|
Drives were not recognized after storage node replacement. |
Action to be taken when drives cannot be recognized (Bare metal) |
|
|
Adding drives |
The added drives could not be recognized. |
Action to be taken when added drives cannot be recognized (Bare metal) |
|
Performance was degraded after drive addition. |
Action to be taken when performance is degraded |
|
|
Removing drives |
The locator LED could not be turned on/off. |
Action to be taken when a locator LED cannot be turned on/off (Bare metal) |
|
The on/off state of the locator LED that is displayed in REST API/CLI/VSP One SDS Block Administrator and the on/off state of the locator LED on the physical drive do not match. |
||
|
Replacing drives |
The locator LED could not be turned on/off. |
Action to be taken when a locator LED cannot be turned on/off (Bare metal) |
|
The on/off state of the locator LED that is displayed in REST API/CLI/VSP One SDS Block Administrator and the on/off state of the locator LED on the physical drive do not match. |
||
|
Change or set configuration information |
One of the following occurred when executing the command to change or set the configuration information.
|
Action to be taken for a failure when changing or setting configuration information (Bare metal) |
|
Authenticating a user |
User authentication did not succeed and either of the following occurred.
|
Action to be taken for a user authentication error |
|
Deleting snapshot volumes |
The following occurred when deleting snapshot volumes.
|
Action to be taken for a failure that occurred when deleting snapshot volumes |
|
Collecting VSP One SDS Block dump log files |
One of the following occurred when collecting dump log files for VSP One SDS Block:
|
Troubleshooting a failure that occurs when VSP One SDS Block dump log files are collected |
|
Configuration backup |
An error message was output when creating a backup of configuration information. |
Action to be taken for a failure that occurred when creating a backup of configuration information (Bare metal) |
|
* Including a case where the console window was closed due to an incorrect operation or communication error. |
||