VMware ESXi

Virtual Storage Platform One SDS Block and SDS Cloud Virtual Private Storage Administration

Version
1.19.x
Audience
anonymous
Part Number
MK-24VSP1SDS028-03
ft:lastEdition
2026-04-20

Common settings

In the case of VMware ESXi 6.X (including 5.X), apply the following updates and KBs.

  • VMware ESXi5.5 Update3 and KB2146717

  • VMware ESXi6.0 Update2 and KB2145663

Note that you do not need to change the setting value for SCSI Timeout because this value is 140 seconds by default, which is greater than the requirement for a compute node (120 seconds).

Alternate path software setting

No additional settings are required.

Inter-guest cluster setting