Compute network requirements (iSCSI)

Virtual Storage Platform One SDS Block Bare Metal Setup and Configuration

Version
1.19.x
Audience
anonymous
Part Number
MK-24VSP1SDS025-03
ft:lastEdition
2026-07-06
CAUTION:

ALUA setting must be enabled. If ALUA is disabled, the expected I/O performance may not be achieved. In addition, the load on the internode network may increase beyond the expected level, causing delays in non-I/O processing within the VSP One SDS Block or resulting in processing failures.

The following table lists the compute network requirements to set up an iSCSI connection configuration in VSP One SDS Block.

Item

Requirement

Remarks

Basic configuration

  • Configure as an L2 or L3 network.

  • Configure as a separate network that does not have a connectivity with the internode network.

  • To use the spare node function, the compute networks of the storage nodes and the spare node that belong to the same fault domain need to belong to the same subnet.

  • Use of a combination of iSCSI and NVMe/TCP or FC in the same storage cluster is not allowed.

  • If you reinstall the storage software (VSP One SDS Block), the iSCSI name of VSP One SDS Block will be changed.

  • Configure a physical network that is different from the control network for performance stability and security improvement.

  • When processing is switched to the spare node, the compute network information of the faulty storage node is passed to the spare node; thus, the compute networks of the storage nodes and the spare node that belong to the same fault domain need to belong to the same subnet. When multiple compute ports are set, and each of them makes up a separate subnet, the compute ports of the spare node to which the compute network information is passed also need to make up the same subnets. For the specific example, see Settings of spare node.

Connectivity

OS

  • Windows Server (64-bit)

  • Red Hat Enterprise Linux (64-bit)

  • VMware ESXi

For details about the supported versions, contact customer support.

iSCSI access method

Use either of the following:

  • iSCSI HBA/CNA

  • NIC and software iSCSI initiator

  • iSNS is supported.

  • When a combination of NIC and software iSCSI initiator is used, the iSCSI communication performance viewed from a compute node depends largely on the CPU performance and memory capacity of the compute node.

  • For details about the TCP/UDP port numbers to be used, see TCP/UDP port numbers required for communication.

  • The maximum number of connections per session is 1. Therefore, the MC/S (Multiple Connections per Session) function is not supported.

ALUA setting

Asymmetric Logical Unit Access (ALUA) of the compute node must be enabled.

The system might need to be restarted when the ALUA setting is enabled.

Bandwidth

At least 1-Gbps bandwidth is required.

Perform operation with at least 10-Gbps bandwidth and jumbo frames (MTU = 9000 bytes) for secure performance.

Availability

When the network is redundant, the convergence time from a failure should be two minutes or less.

Make the network redundant so that it has no single point of failure (SPOF) that could disable communication in multiple storage nodes.

An SPOF could cause a single network appliance failure or other link failure to stop I/O operations for the VSP One SDS Block cluster.

Security

Use CHAP authentication or build an IP SAN completely independent of an external environment to prevent unauthorized access.

 

Monitoring

Equipped with a network monitoring system independent of VSP One SDS Block to detect network failures and performance degradation (switch failures, link failures, increased delays, increased packet loss, connections at unexpected link speed operating values and duplex operating values, and others.), and configure it so that the cause can be identified.

If the internode network is not provided with a monitoring system, it might be impossible to troubleshoot network failures or performance degradation.

Expandability

Determine a network topology and allocate IP addresses in consideration of the possibility that storage nodes might be added in the future.

Network topology

  • The network topology must be designed taking into account redundant configuration and future expansion.

  • All compute ports are reachable from the compute node.

A configuration of two targets per storage node is recommended.

Maximum transfer length per I/O request

The transfer length per I/O request that reaches the volume from the compute node must be 8 MiB or less.

Typically, the maximum I/O size that reaches the volume can be limited by the settings of the compute node OS, driver, HBA, or hypervisor.

Depending on the compute node configuration and settings, I/O requests exceeding 8 MiB might be sent to the volume without being split.

In that case, VSP One SDS Block outputs an event log. Follow the instructions in the VSP One SDS Block and SDS Cloud Troubleshooting Reference to resolve the issue.