ALUA setting must be enabled. If ALUA is disabled, the expected I/O performance may not be achieved. In addition, the load on the internode network may increase beyond the expected level, causing delays in non-I/O processing within the VSP One SDS Block or resulting in processing failures.
The following table lists the compute network requirements to set up an iSCSI connection configuration in VSP One SDS Block.
|
Item |
Requirement |
Remarks |
|
|---|---|---|---|
|
Basic configuration |
|
|
|
|
Connectivity |
OS |
|
For details about the supported versions, contact customer support. |
|
iSCSI access method |
Use either of the following:
|
|
|
|
ALUA setting |
Asymmetric Logical Unit Access (ALUA) of the compute node must be enabled. |
The system might need to be restarted when the ALUA setting is enabled. |
|
|
Bandwidth |
At least 1-Gbps bandwidth is required. |
Perform operation with at least 10-Gbps bandwidth and jumbo frames (MTU = 9000 bytes) for secure performance. |
|
|
Availability |
When the network is redundant, the convergence time from a failure should be two minutes or less. |
Make the network redundant so that it has no single point of failure (SPOF) that could disable communication in multiple storage nodes. An SPOF could cause a single network appliance failure or other link failure to stop I/O operations for the VSP One SDS Block cluster. |
|
|
Security |
Use CHAP authentication or build an IP SAN completely independent of an external environment to prevent unauthorized access. |
||
|
Monitoring |
Equipped with a network monitoring system independent of VSP One SDS Block to detect network failures and performance degradation (switch failures, link failures, increased delays, increased packet loss, connections at unexpected link speed operating values and duplex operating values, and others.), and configure it so that the cause can be identified. |
If the internode network is not provided with a monitoring system, it might be impossible to troubleshoot network failures or performance degradation. |
|
|
Expandability |
Determine a network topology and allocate IP addresses in consideration of the possibility that storage nodes might be added in the future. |
||
|
Network topology |
|
A configuration of two targets per storage node is recommended. |
|
|
Maximum transfer length per I/O request |
The transfer length per I/O request that reaches the volume from the compute node must be 8 MiB or less. |
Typically, the maximum I/O size that reaches the volume can be limited by the settings of the compute node OS, driver, HBA, or hypervisor. Depending on the compute node configuration and settings, I/O requests exceeding 8 MiB might be sent to the volume without being split. In that case, VSP One SDS Block outputs an event log. Follow the instructions in the VSP One SDS Block and SDS Cloud Troubleshooting Reference to resolve the issue. |
|