Performing bulk obtainment of storage cluster configuration information

Virtual Storage Platform One SDS Block Bare Metal Setup and Configuration

Version
1.19.x
Audience
anonymous
Part Number
MK-24VSP1SDS025-03
ft:lastEdition
2026-07-06

This section describes the procedure for verifying the configuration by using a REST API/CLI to obtain a summary of storage cluster configuration information.

  1. Start a terminal in the controller node.
  2. Change the password of the user created in the "ServiceAdministrators" user group, according to the procedure described in Creating an initial user. The parameters and values required to change the password are as follows:
    • userId: ID of the user created in the "ServiceAdministrators" user group

    • currentPassword: Password used when the user was created

    • newPassword: New password

    REST API: PATCH /v1/objects/users/<userId>/password

    CLI: user_password_set

    In the following steps, use the same credentials as in step 2.

  3. Obtain a list of event logs and verify that startup of the storage cluster is completed before confirming configuration.

    REST API: GET /v1/objects/event-logs

    CLI: event_log_list

    If the KARS08100-I message has been output to the event log, startup of the storage cluster is completed. Perform the following procedures to confirm each configuration.

  4. Obtain a summary of the storage cluster configuration information to verify the configuration.

    REST API: GET /v1/objects/storage-configuration-summary

    CLI: storage_configuration_summary_show

    Verify the obtained information to make sure of the following.

    Item

    Obtained information

    Verification

    storage

    Value of softwareVersion from which dots (.) are excluded

    This value is the same as the <version> value of the storage software installer file (hsds-installer-vssb-<version>-<number>.iso) that is used in Installing the storage software.

    status

    The status value is "Ready."

    internalId

    If you make multiple configurations of VSP One SDS Block, each internalId must be different.1

    storageTimeSetting

    systemTime

    The systemTime value is the same as the time of the NTP server.

    faultDomains

    status

    The status value is "Normal."

    numberOfStorageNodes

    Meet all of the following:

    • All faultDomain objects have the same value
    • The sum of the values is equal to the number of storageNode objects obtained simultaneously

    storageControllers

    status

    The status value is "Normal."

    storageNodes

    Number of storageNode objects

    The number of objects and the number of lines in the [Nodes] section of the VSSB configuration file are the same.

    status

    The status value is "Ready."

    memory

    The value is the same as the memory capacity installed in each storage node.

    biosUuid

    For verification in troubleshooting, record the biosUuid values of the storage nodes for which the clusterRole value is "Master."

    controlPorts

    status

    The status value is "Normal."

    isTeamingEnabled

    Teaming configuration is made as expected.

    teaming: primaryPortSpeedDuplex

    Both the link speed and duplex setting have expected values.

    teaming: secondaryPortSpeedDuplex

    Both the link speed and duplex setting have expected values.

    internodePorts

    status

    The status value is "Normal."

    teaming: primaryPortSpeedDuplex

    Both the link speed and duplex setting have expected values.

    teaming: secondaryPortSpeedDuplex

    Both the link speed and duplex setting have expected values.

    ports

    protocol

    The protocol is as expected.

    status

    The status value is "Normal."

    macAddress2,3

    Verification is required only when the iSCSI or NVMe/TCP protocol is used.

    (For Hitachi Advanced Server HA800 series, HA800 G2 series, HA800 G3 series, and HA800 G6 series) After you select System Information in the navigation tree of the iLO web interface window, this value must be the same as the compute port MAC address in Network.

    (For physical servers other than Hitachi Advanced Server HA800 series, HA800 G2 series, HA800 G3 series, and HA800 G6 series) This value must be the same as the compute port MAC address confirmed in the BMC web interface window.

    pools

    status

    The status value is "Normal."

    drives

    Number of drive objects

    The number must be the same as that of drives added to the storage node.

    statusSummary

    The statusSummary value is "Normal."

    1. If the internalId value is duplicated in any other VSP One SDS Block, perform the operation described in Removing the storage software in the VSP One SDS Block and SDS Cloud System Administration. Then, perform the operation again from Installing the storage software.

    2. Verify this address if you configured ports in the Network port configuration window.

    3. (For physical servers other than Hitachi Advanced Server HA800 series, HA800 G2 series, HA800 G3 series, and HA800 G6 series) For details about specific procedures, see the respective server vendor documentation.