Configure a storage cluster by using the storage nodes for which the setup of each storage node is complete. Use the BMC remote console to perform this procedure.
-
Connection to the networks used for storage cluster must be complete.
-
Connection from the controller node to the control network must be completed.
-
The VSSB configuration file containing the storage cluster configuration information must be stored in the controller node.
-
The setup of each storage node has been completed for all storage nodes to be used, and the status of the storage node must be "NodeSettingCompleted."
-
The time of all storage nodes to be used must be synchronized.
-
The storage software version must be the same on all storage nodes to be used.
- The NTP server must be normally running.
- The NTP server must be synchronized with the high-level NTP server correctly, if synchronization with such servers has been performed.
- If IP addresses for which connection is permitted has been set on the NTP-server side, the control port IP address and representative IP address of the storage node must also be permitted.
- To use an FQDN in NTP, Syslog, e-mail (SMTP), SNMP, or external authentication
servers (LDAP server), the following conditions must be met when setting a DNS
server with a VSSB
configuration file.
- The DNS server must be normally running.
- The DNS record for resolution of FQDNs must be correctly set in the DNS server.
- If IP addresses for which connection is permitted has been set on the DNS-server side, the control port IP address and representative IP address of the storage node must also be permitted.
-
For the status of the storage node, verify the value of Storage node status on the Top menu screen.
-
If you perform this procedure for the second time, the status of the storage node might be "ClusterSetupTemporaryStopped." When that occurs, change the status of the storage node to “NodeSettingCompleted” by performing the following steps, and then perform this procedure:
-
From the Top menu screen, select Cancel cluster setup (for this storage node).
-
In the Cancel cluster setup (for this storage node) screen, select Submit.
-
-
For the time of the storage node, check the time area of the Top menu screen.
-
For the storage software version of the storage node, check the value of Software version on the Show setting screen.
If there are storage nodes that are out of time, the storage cluster configuration process might be unsuccessful.
Notes on the procedure
-
Perform this procedure only for one storage node of your choice (referred to as representative storage node hereafter). Do not change the target storage node during the procedure.
-
Communication is performed from the representative storage node to other storage nodes to configure a storage cluster.
-
For details about how to operate BMC (such as how to display and operate the BMC web interface window and how to operate the BMC remote console), see the BMC User Guide provided by the vendor of the physical server.
About the console interface screen
For details about the items that are displayed on the console interface screen and how to use the screen, see Items displayed on the console interface screen and how to use the screen.
If an event that should be notified to the user occurs, a message and message ID are shown in the console interface.
For details about action to be taken when this message appears, see [Solution] of the corresponding message description in the VSP One SDS Block and SDS Cloud Message Reference.