Server replacement requirements

Virtual Storage Platform One File 32 Gen2 Hardware Reference

Version
15.6.x
Audience
anonymous
Part Number
MK-24VSP1F009-00
ft:lastEdition
2026-08-28

Consider the following server replacement requirements:

  • Much of the process required for a server replacement is the same as what is covered in installation and configuration training.
  • Determine which replacement scenario is being encountered. The replacement process is different for each scenario.
Note: The VSP One File replacement servers do not have the option to install an embedded system management unit (SMU), so any communication to the replacement server must be either through a serial/KVM connection or through File Management Software.
You can connect to the server directly via KVM (using a keyboard, video, and mouse) or a serial connection using a serial cable and a USB to Serial dongle. Bring these with you in case they are needed when the unit arrives. If you connect to the serial port, use the following Serial client settings:
  • 115,200 b/s
  • 8 data bits
  • 1 stop bit
  • No parity
  • No flow control