The following table lists parameters that can be set for CCI options and indicates the range for each parameter.
|
Parameter |
Range |
|---|---|
|
Mirror ID (MU#) |
0 |
|
CTG ID |
0 to 127 for VSP One B80 series, 0 to 255 for VSP One B85 |
|
Path group ID |
0 to 255 |
|
Maximum initial copy activities |
1 to 512 |
|
Maximum initial copy activities per CU |
1 to 16 |
|
Blocked path monitoring time |
2 to 200 seconds (VSP One B20 series) The range is 2 to 45 seconds when the DKCMAIN firmware version is earlier than A3-04-21-xx/xx. (VSP One B20 series) The same range of values is used for TrueCopy, Universal Replicator, and global-active device. |
|
Blocked path SIM monitoring time |
2 to 200 seconds (VSP One B20 series) The range is 2 to 100 seconds when the DKCMAIN firmware version is earlier than A3-04-21-xx/xx. (VSP One B20 series) The same range of values is used for TrueCopy, Universal Replicator, and global-active device. |