Universal Replicator

Global Active Device for VSP One Block

Version
10.5.x
Audience
anonymous
Part Number
MK-23VSP1B011-10
ft:lastEdition
2026-05-04

You can combine GAD and Universal Replicator to create a configuration that can continue to operate in the event of a multi-site failure.

In a GAD system, the server accesses the primary and secondary sites simultaneously and shares the same data between the two sites (at campus distance). If a failure occurs at one site, you can continue operations at the other site. However, if a failure occurs at both sites, for example due to a large-scale disaster, you will not be able to continue operations with the data redundancy provided only by GAD.

To manage this situation, you can implement a 3-data-center (3DC) configuration by combining GAD and Universal Replicator (UR). This configuration is called a GAD 3DC delta resync (GAD+UR) configuration. If there is a failure at both the primary site and the GAD secondary site, the GAD+UR configuration enables you to continue operations using the UR secondary site (at metro distance).

Note:
  • (VSP One Block 20 series) If a GAD pair is created by using volumes connected to a host via NVMe-oF, UR cannot be used with GAD. A 3DC delta resync configuration with GAD and UR is not supported.
  • The CCI remote command device is not required in GAD+UR configurations.
  • Volumes in a 3DC GAD+UR configuration cannot be shared with the following volumes:
    • UR volumes in a system with multiple storage systems in the primary and secondary sites
    • UR volumes in a 3DC multi-target configuration with TC and UR
    • UR volumes in a 3DC multi-target configuration with 3 UR sites
    • UR volumes in a 3DC cascade configuration with 3 UR sites
  • 3DC delta resync configuration with GAD and UR is supported by VSP One B26, VSP One B28, and VSP E series.
    In this configuration, VSP One B26 and VSP One B28 can be connected with the following storage systems:
    • VSP E1090
    • VSP E990, VSP E790, VSP E590

The following table lists the combinations of the storage system models and the required DKCMAIN versions in a 3DC delta resync configuration with GAD and UR.

Combination of storage system models DKCMAIN version
VSP One B26 or VSP One B28 and VSP E590 or VSP E790 or VSP E990 or VSP E1090 VSP One B26, VSP One B28: All versions
VSP E590, VSP E790, VSP E990, VSP E1090: 93-07-23 or later

The following figure shows the required configuration for GAD+UR operations. You must use this configuration when combining GAD with UR.



In a GAD+UR configuration:

  • The P-VOL of the GAD pair functions as the P-VOL of the UR pair.
  • The S-VOL of the GAD pair functions as the P-VOL of the UR delta resync pair.
  • The UR S-VOL has two mirror IDs, one for the UR pair, and one for the UR delta resync pair.
  • The UR delta resync pair consists of the GAD S-VOL at the GAD secondary site and the UR S-VOL at the UR secondary site. This UR delta resync pair allows you to synchronize the UR pair S-VOL by using the journal data at the GAD secondary site in the event of a failure at the primary site.
  • When combining GAD with UR, create the GAD pair first, and then create the UR pair. The GAD pair cannot be used with a UR pair that was created first.

A special case for using the GAD+UR configuration is to migrate the UR environment between the current primary and secondary sites to different primary and secondary sites while keeping the UR pairs.